Troubleshooting · plasma
Torch height control (THC) troubleshooting: hunting, diving or climbing torch
Why the THC hunts, dives in corners or over voids, or lifts the torch: arc voltage, anti-dive, activation delay, worn consumables, grounding. A step-by-step diagnostic method.
Torch height control (THC) holds a constant arc voltage; since voltage rises with arc length, it moves the torch up or down to keep the setpoint. But it’s an indirect height measurement: anything that changes voltage without changing height fools the THC. Avid CNC sums up the typical cases well: lead-ins/outs, tight corners, small holes, and moving over voids.
Symptom → cause → fix
| Symptom | Likely cause | Fix |
|---|---|---|
| Torch dives in corners | Machine slows, voltage rises, THC goes down | Velocity-based anti-dive (corner hold); threshold near cut speed depending on the control |
| Dives over an already-cut part (void) | No metal under the torch, voltage climbs | Voltage-change anti-dive (void sensing), cut order, avoid crossing voids |
| Constant oscillation (hunting) | THC gain/speed too high, electrical noise, unstable setpoint | Reduce sensitivity, check ground and wiring, filtering per the manufacturer |
| Torch slowly climbs during the cut | Worn consumables (voltage rises with wear), setpoint too high | Replace electrode/nozzle; back to the chart |
| Torch drags on the plate | Setpoint too low, warped sheet, THC too slow | Back to chart voltage, more responsive material profile |
| Dive at the lead-in | THC activated too early, while speed builds | Activation delay after pierce (THC delay) |
| Erratic behaviour everywhere | Poor grounding, damaged ground cable, HF interference | Direct ground on table and plate, separated cables, manufacturer’s procedure |
Diagnostic method
- Back to basics: new consumables, plasma source chart (current, height, voltage, speed); see Reading cut charts.
- Check IHS (initial height sensing): pierce height depends on good sensing (ohmic or float).
- Cut a straight line on a flat sheet with THC on: if it already oscillates, it’s tuning or electrical.
- Add corners and small holes: if it only dives there, it’s anti-dive.
- Cut across an already-cut slot: tests void detection.
- Read the log if the control has one (Mach4 at Avid, QtPlasmaC) and mark problem spots.
Common mistakes
| Mistake | Consequence |
|---|---|
| Raising sensitivity to “follow” the sheet | Oscillation |
| Same voltage from new to worn electrode | Height drifts |
| THC active for the whole program | Dives at holes and corners |
| Voltage divider misconfigured | Wrong reading, inconsistent THC |
Checklist
- New consumables matching the chart
- Target voltage = chart (adjusted only after testing)
- THC activation delay after pierce set
- Anti-dive enabled (velocity and/or void)
- THC inhibited on small holes
- Ground checked (table, plate, power source)
FAQ
Should THC always be used?
Not on very small parts or very thin, flat sheets, where fixed height after sensing can be enough. On large warped sheets, yes.
My displayed voltage isn’t the chart’s: is that wrong?
Not necessarily: divider, wiring and wear change the reading. What matters is cut quality and actual height (check with a gauge).
Sources
- Avid CNC — Mach4 Plasma Users Guide (THC theory and tuning), consulted November 26, 2026.