Troubleshooting · reference
CNC, plasma and laser error codes and alarms
406 codes and messages from official manuals (Haas, Siemens, FANUC, Hypertherm, ESAB, Lincoln, Grbl…), in English and French, with the source under each table. Type the code as it appears.
No code found. Check the brand, try without dashes or with a word from the message.
First response to an alarm (read once)
- Make it safe. E-stop if anyone or anything is at risk. Never reach into the work zone of a machine in alarm without lockout.
- Write it all down before pressing RESET: number, exact text, axis, program block or line, what the machine was doing. A photo of the screen is enough.
- Read the alarm history: the first alarm in the chain is often the real cause (e.g. overload followed by overcurrent = crash).
- Look the code up here, then in your machine’s manual: builders often add their own (PLC) alarms.
- Fix one cause at a time and test at reduced speed (single block, reduced feed, dry run).
- Call service for anything inside the electrical cabinet, drives, or an alarm that keeps coming back. Give them your notes.
CNC controls (mill, lathe)
Haas — Haas control (NGC and Classic) 19
On the NGC, axis alarms read axis.alarm: 1.108 = alarm 108 on the X axis (1 = X, 2 = Y, 3 = Z, 5 = A, 6 = B, 7 = C).
| Code | Meaning | What to check |
|---|---|---|
107 | EMERGENCY STOPAn emergency stop button is pressed. Haas asks you to confirm alarm 107 appears during the monthly test of each e-stop. | Find the cause, release the e-stop, then RESET. |
103 / 104 / 105 | SERVO ERROR TOO LARGEFollowing error too large on an axis (Classic control). Haas lists poor ballscrew lubrication first; rough motion or noise when jogging. | Check ballscrew lubrication; inspect screw, nut and coupling. |
108 (CHC) · 1.108 (NGC) | X SERVO OVERLOAD / X AXIS SERVO OVERLOADX-axis servo overload. On the NGC, 108 covers every axis: 2.108 = Y, 3.108 = Z, 5.108 = A, 6.108 = B, 7.108 = C (Classic control: 109 Y, 110 Z, 111 A, 188 B, 271 C). | Haas lists a dull or damaged tool and ballscrew misalignment; overcurrent alarms that follow point to a crash. |
253 | ELECTRONICS OVERHEATElectrical cabinet temperature reached the limit (the “Electronics Overheat” icon warns first). | Clean or replace the cabinet air filters; check the fans. |
314 | SUBPROGRAM NOT IN MEMORYThe called subprogram (e.g. a G150 P###) is not found internally or externally. | Check the P or N number and that the subprogram is loaded. |
332 | H AND T NOT MATCHEDSetting 15 (H & T code agreement) is on and the H number does not match the T. | Fix the H in the program (or review Setting 15). |
339 | MULTIPLE CODESManual example: an M-code placed before G65 on the same line (M14 G65 P1000). | Put the M-code after G65 (G65 P1000 M14). |
370 | POCKET DEFINITION ERRORG150 pocket badly defined: open contour or X-Y start point outside the boundary. | Close the subprogram contour; start inside it. |
467 | (G02/G03 avec réglages 188–190)With Settings 188–190 in effect, only linear G01 is allowed; a G02 or G03 triggers alarm 467. | Turn those settings off or replace the arcs. |
973 | FIXTURE CLAMP INCOMPLETEFixture clamp monitoring (M90, Setting 276) is on and the spindle was commanded while the clamp input is not confirmed (#709 = 1). | Check the clamp and its sensor; M91 turns monitoring off. |
2062 | TCPC OR DWO INCOMPATIBLE CODEWrong call order: G268/G269 used with G234 without calling G268 first. | Call G268 before G234. |
2073 | AXIS LUBRICATION PRESSURE NOT DETECTEDHaas Liquid Grease: pressure not detected for 5 consecutive lube cycles. | Refill grease; check manifold, lines, fittings and pressure switch. |
2075 | AXIS LUBRICATION RESERVOIR IS EMPTYLiquid grease: pressure drops below 4 psi before 15 s for 5 cycles. | Refill with Haas grease or an approved equivalent. |
2082 | RESIDUAL PRESSURE DETECTED PRIOR TO AXIS LUBRICATION CYCLEResidual pressure before the cycle: blockage in the grease circuit. | Inspect orifices, lines, fittings and manifolds; purge clogged lines. |
4030 | AUTOFEED MINIMUM THRESHOLD REACHEDAutofeed reached its minimum feed. | Reduce cutting load or review Autofeed settings. |
9300 | BROKEN TOOL DETECTEDBroken Tool Detection: tool length before and after use differs; the BTD page opens with both photos. | Inspect the tool and the part before resuming. |
1.9930 | X SERIAL ENCODER COMMUNICATION FAULTHaas example of the NGC axis-alarm format: X-axis serial encoder communication fault. | In the alarm viewer, search for “9930” only. |
9100.018 | NON RESETTABLE Software ErrorHaas example of the “alarm.sub-alarm” format: the part after the point narrows the cause. | Note the full number for Haas service. |
20000–20017 | (messages d’information)Information messages, mostly at power-up, shown only in the history; e.g. 20016 Touchscreen not detected. | Normally no action needed. |
Sources: Haas — Mill Operator’s Manual, Next Generation Control (96-8210, rév. V, déc. 2025); Haas — Ballscrew Troubleshooting Guide (TG0038); Haas — Axis Assignments, NGC (RD0003); Haas — Haas Liquid Grease Troubleshooting Guide (TG0079); Haas — Alarm Search Help Guide (RD0002) · consulted November 26, 2026
FANUC — FANUC Alpha i amplifiers (7-segment display) 9
These codes show on the amplifier’s display inside the cabinet, not on the control screen. Control alarms (PS, SV, OT, SR…) are in your model’s maintenance manual (e.g. 0i-F: B-64605EN); FANUC does not publish it openly, so we do not reproduce them.
| Code | Meaning | What to check |
|---|---|---|
1 (servo) | Alarme 1 — amplificateur servoServo amplifier internal cooling fan failure. | Fan diagnostics, inspection, replacement. |
2 (alimentation) | Alarme 2 — module d’alimentationPower supply internal cooling fan failure. | Inspect and replace the fan. |
5 | Alarme 5 — amplificateur servoLow DC link voltage. | Check the power supply, measure voltages, isolate the fault (qualified staff). |
8. / 9. / A. | Alarme 8., 9. ou A. — amplificateur servoIPM power module overheating. | Check cooling and axis load. |
F | Alarme F — amplificateur servoExternal cooling fan failure. | Inspect and replace the external fan. |
U / L | Alarme U ou L — amplificateur servoCommunication error on the FSSB fibre-optic network. | Check fibre cables, connectors and amplifier communication. |
56 (broche) | Alarme 56 — amplificateur de brocheSpindle amplifier internal cooling fan failure. | Inspect and replace the fan. |
88 (broche) | Alarme 88 — amplificateur de brocheSpindle amplifier external cooling fan failure. | Inspect and replace the fan. |
BAT | BAT (commande)Memory backup battery low: risk of losing SRAM data (parameters, programs, offsets). | Back up data, then replace the battery per FANUC’s procedure. |
Source: FANUC America — CNC Tech Tips (alarmes d’amplificateurs Alpha i, batterie) · consulted November 26, 2026
Siemens — SINUMERIK 828D (most also apply to 840D sl) 32
%1, %2… in the text are replaced on screen by the channel, block or axis. Alarms 700000 and up are PLC alarms defined by the machine builder: see their documentation.
| Code | Meaning | What to check |
|---|---|---|
2000 | PLC sign-of-life monitoringThe PLC gave no sign of life within the set time; also triggered by a PLC stop. | Authorized service: find the cause in the PLC (loop or program stop). |
2001 | PLC has not started upThe PLC gave no sign of life after power-up. | Authorized service: check PLC start-up. |
3000 | Emergency stopEmergency stop request received on the NC/PLC interface. | Remove the cause, acknowledge the e-stop, RESET, restart the program. |
8080 | %1 option(s) is/are activated without setting the license keyOptions activated without a licence key. | Enter the licence key (Setup > Licenses). |
10208 | Continue program with NC startInformation: after block search with calculation the control is ready; resume with NC Start. | Press NC Start (or adjust in JOG first). |
10620 | Block %3 axis %2 at software limit switch %4During motion the axis would hit the software limit (handwheel overlay, offset or transformation). | Check offsets (frame) and part or fixture position. |
10621 | Axis %2 rests on software limit switch %3%4The axis is resting on its software limit. | Jog the axis back the other way. |
10720 | Block %3 axis %2 software limit switch %4The programmed path exceeds the software limit (found during block preparation). | Fix program positions, work offsets and tool offsets. |
10730 | Block %3 axis %2 working area limitation %4The programmed path exceeds the working area limitation. | Fix the program or the working area limitation. |
10870 | Block %2 facing axis for constant cutting speed not definedConstant cutting speed (G96) selected with no facing axis defined. | Define the reference axis (SCC[AX]) or check configuration. |
12080 | Block %2 syntax error in text %3Syntax error in the block; the offending text is shown. | Fix the block (often the wrong post processor). |
12550 | Block %2 name %3 is not known or not definedName (variable, subprogram, cycle) unknown or not defined. | Check spelling, definition and that the cycle is loaded. |
14011 | Block %2 program %3 not existing or will be editedThe called program does not exist or is open for editing. | Check name and directory; close the editor. |
14051 | Block %2 arithmetic error in part programArithmetic error in the part program. | Fix the calculation or variables (e.g. division by zero). |
14080 | Block %2 jump destination %3 not foundJump destination (GOTO, label) not found. | Check the label and search direction (GOTOF/GOTOB). |
14760 | Block %2 auxiliary function of a group programmed repeatedlyTwo M/H functions from the same group in one block. | Split the functions into separate blocks. |
16100 | Block %2 spindle %3 not available in the channelSpindle number not known in this channel. | Fix the programmed spindle number. |
17040 | Block %2 illegal axis indexAccess to an axis variable whose name does not map unambiguously to a machine axis. | Fix the axis name in the program. |
17190 | Block %2 illegal T number %3The called tool is not defined (T number, name or magazine location). | Create or fix the tool in the tool list. |
20000 | Axis %2 reference cam not reachedHoming: the reduction cam is not reached within the maximum distance (incremental encoders). | Check the cam, its sensor and wiring. |
20001 | Axis %2 no cam signal presentHoming: the cam signal was lost at the start of phase 2. | Check the cam and its sensor. |
21610 | Axis %2 encoder %3 frequency exceededMaximum encoder frequency exceeded: the position reference may be lost. | Check speed and encoder; re-home. |
21612 | Axis %2: enable reset, cause %3Axis enable removed during motion (cause 1: servo enable missing; 2: pulse enable missing…). | Read the cause number; check safety chain and drive. |
22270 | Block %2 thread cutting: Maximum speed axis %3 exceeded %4Thread cutting G33/G34/G35: the calculated axis speed exceeds the maximum. | Lower spindle speed or review the pitch. |
25000 | Axis %1 hardware fault of active encoderHardware fault of the active encoder. | Check encoder, cables, connectors and shielding. |
25001 | Axis %1 hardware fault of passive encoderHardware fault of the passive encoder. | Check encoder, cables, connectors and shielding. |
25040 | Axis %1 standstill monitoringThe axis does not stay within the standstill position tolerance. | Check brake, control tuning, mechanical load. |
25050 | Axis %1 contour monitoringToo large a gap between actual position and the internal model’s expected position (contour tolerance). | Check mechanics (binding, crash) and control tuning. |
25060 | Axis %1 speed setpoint limitationThe speed setpoint stayed at its limit too long. | Check load, mechanical binding and drive. |
25080 | Axis %1 positioning monitoringThe axis did not reach the exact-stop window within the positioning time. | Service: review exact-stop limits and control tuning. |
25201 | Axis %1 drive faultSerious drive fault. | Read the drive alarms for the exact cause. |
26101 | Axis %1 drive %2 communication failureThe drive is not communicating (PROFIdrive). | Check the drive link and power. |
Source: Siemens — SINUMERIK 828D / SINAMICS S120, Alarms, Diagnostics Manual (04/2026) · consulted November 26, 2026
Mazak — Mazatrol M-32 (1995 manual) 6
These numbers come from the M-32 manual. Newer Mazatrol controls (Matrix, Smooth) have their own lists, not openly published: do not carry these numbers over.
| Code | Meaning | What to check |
|---|---|---|
008 | BATTERY ALARMThe battery that keeps parameters and programs is low or dead. | Check data, recharge or replace the battery (maintenance manual). |
052 | MOTOR OVERHEATMotor overheated (run above continuous rating). | Reduce acceleration/deceleration frequency or cutting load. |
053 | OVERLOAD 1Servo motor run above its rating. | Reduce acceleration/deceleration or cutting load. |
055 | SERVO LAG EXCESSExcessive gap between actual and commanded position: crash or detector/cable problem. | Free the machine from the crash; otherwise call Mazak service. |
056 | EMERGENCY STOP (EXTERNAL)Emergency stop signal from the NC or the machine. | Find and remove the cause of the e-stop. |
064 | OVERTRAVELAn axis reached its stroke limit; auto cycle cannot start. | Jog the axis off the limit; otherwise look for a broken wire or bad limit switch. |
Source: Mazak — Alarm & Parameter Manual, Mazatrol M-32 (publication C731SA0551E, 1995; copie publique) · consulted November 26, 2026
LinuxCNC — LinuxCNC (messages) 2
LinuxCNC has no numeric codes: it shows messages. The settings involved are in the INI file.
| Code | Meaning | What to check |
|---|---|---|
joint N following error | joint N following errorThe joint deviates from commanded position by more than allowed: MIN_FERROR at very low speed, ramping up to FERROR at speed. | Check mechanics, max velocity and acceleration, motor tuning; only raise FERROR knowingly. |
soft limit | (MIN_LIMIT / MAX_LIMIT)The move exceeds an axis soft limit: the controller aborts motion. Limits only apply after homing. | Check the work offset and program; re-home. |
Source: LinuxCNC — Documentation, INI Configuration (FERROR, MIN_FERROR, MIN_LIMIT, MAX_LIMIT) · consulted November 26, 2026
Plasma
Hypertherm — Powermax65/85/105 SYNC 33
Format 0-nn-n: the last digit narrows the cause. 1-nn-n, 2-nn-n and 3-nn-n codes are internal faults: service required.
| Code | Meaning | What to check |
|---|---|---|
0-11-0Alert | Remote operating mode not allowed for the cartridge (1 = cut, 2 = expanded metal, 3 = gouge). | Check the process variables sent by the CNC. |
0-11-1Alert | Remote output current not allowed for the cartridge. | Check the CNC process variables. |
0-11-2Alert | Remote gas pressure not allowed. | Check the CNC process variables. |
0-12-1Alert | Gas output pressure low. | Increase inlet pressure. |
0-12-2Alert | Gas output pressure high. | Decrease inlet pressure. |
0-12-3Alert | Gas output pressure unstable. | Check regulator, lines and air supply. |
0-13-0Alert | AC input power unstable (warning). | Check the line or generator. |
0-14-0Alert | Cartridge installation problem. | Reinstall the cartridge; reduce nearby electrical noise. |
0-14-1Alert | Cartridge not recognized. | Clean and inspect the cartridge; set current manually if needed. |
0-19-9Stops | Input power stopped or power-board hardware protection. | Check input power; if repeated, service. |
0-20-0Alert | Gas pressure below the minimum for the process, torch, lead length and cartridge. | Increase inlet pressure; check leaks and filters. |
0-21-0Stops | Gas flow lost while cutting (excessive arc-voltage change). | Check gas supply and lines. |
0-22-0Stops | No gas supply input. | Connect and open the gas supply. |
0-30-0Stops | Torch stuck open (TSO): nozzle and electrode stay touching after the start signal. | Power off, replace the cartridge, power on. |
0-30-1Stops | Torch stuck closed (TSC): nozzle and electrode separate after the start signal. | Power off, correct, power on; if persistent, torch damaged. |
0-32-0Stops | Cartridge at end of life. | Install a new cartridge. |
0-32-1Alert | A cartridge that already had 0-32-0 is reinstalled. | Install a new cartridge. |
0-40-0 / 0-40-1Stops | Boost PFC IGBT too cold / too hot (CSA and 105 SYNC CE models). | Let it cool with power on (fan) or warm the room; clear the louvres. |
0-40-2 / 0-40-3Stops | Inverter IGBT too cold / too hot. | Same steps: cooling, ambient temperature, fan clearance. |
0-50-0Stops | Cartridge off, torch disconnected, or torch lock yellow at restart. | Power off, install the cartridge, power on. |
0-50-1Stops | Torch-lock switch in the yellow (X) position. | Set the switch to green (ready). |
0-50-2Info | Lock switch green but torch not ready to fire. | Hand torch: release and press the trigger. Machine: send STOP from the CNC if the code stays. |
0-50-3Info | System is reading cartridge data. | Wait (up to 6 s with electrical noise). |
0-51-0Stops | Start signal present at power-up (“stuck start”). | Release the trigger or remove the CNC signal, then restart. |
0-52-0Stops | Torch not connected. | Plug the torch into FastConnect and restart. |
0-60-0Stops | AC input phase loss (three-phase models). | Check phases and fuses. |
0-60-1Stops | AC input voltage too low. | Check the line. |
0-60-2Stops | AC input voltage too high. | Check the line. |
0-61-0Stops | AC input unstable: shutdown. | Power down and fix the line problem first. |
0-98-0Alert | Internal communication failure (LCD/control PCB and DSP PCB). | Power off 20 s, restart; if persistent, service. |
0-98-1Alert | RF communication failure between cartridge and torch. | Clean and reinstall the cartridge. |
0-98-2Alert | Communication failure between torch and power supply. | Check the torch connection. |
1-nn-n · 2-nn-n · 3-nn-nStops | Major internal component fault in the power supply. | Service by a qualified technician. |
Source: Hypertherm — Powermax65/85/105 SYNC Operator Manual (810470, rév. 4.1, juillet 2026) · consulted November 26, 2026
Hypertherm — Powermax65/85/105 (pre-SYNC) 16
Labels from Hypertherm’s machine-side reference guide; detailed solutions are in section 5 of the operator manual.
| Code | Meaning | What to check |
|---|---|---|
0-12 | Low input gas pressure: warningLow input gas pressure (warning). | See section 5 of the operator manual. |
0-13 | AC input unstable: warningAC input unstable (warning). | See section 5 of the operator manual. |
0-19 | Power board hardware protectionPower board hardware protection. | See section 5 of the operator manual. |
0-20 | Low gas pressureLow gas pressure. | See section 5 of the operator manual. |
0-21 | Gas flow lost while cuttingGas flow lost while cutting. | See section 5 of the operator manual. |
0-22 | No gas inputNo gas input. | See section 5 of the operator manual. |
0-30 | Torch consumables stuckConsumables stuck (torch stuck open or closed). | See section 5 of the operator manual. |
0-32 | End of consumable lifeEnd of consumable life. | See section 5 of the operator manual. |
0-40 | Over temperaturePower supply temperature out of range. | See section 5 of the operator manual. |
0-50 | Retaining cap offRetaining cap off or not fully threaded. | See section 5 of the operator manual. |
0-51 | Start/trigger signal on at power upStart/trigger signal on at power-up. | See section 5 of the operator manual. |
0-52 | Torch not connectedTorch not connected. | See section 5 of the operator manual. |
0-60 | AC input voltage errorAC input voltage error (phase loss, over- or under-voltage). | See section 5 of the operator manual. |
0-61 | AC input unstable: shutdownAC input unstable: shutdown. | See section 5 of the operator manual. |
0-98 | Internal communication failureInternal communication failure. | See section 5 of the operator manual. |
0-99 | System hardware fault – service requiredMajor hardware fault: service required. | See section 5 of the operator manual. |
Source: Hypertherm — Powermax machine-side reference guide, Powermax65/85/105 · consulted November 26, 2026
Hypertherm — XPR170 / XPR300 / XPR460 (diagnostic codes) 169
Message as shown (in English) on the CNC or XPR web interface. Priorities: Info, Alert, Error, Failure (the arc cannot start). Keep XPR firmware current: some codes come from old firmware.
| Code | Meaning | What to check |
|---|---|---|
500Failure | GCC->Main CAN t/oCAN communication lost between the main board and a module (gas console GCC, torch console TCC, chopper Ch). | Follow the manual’s CAN troubleshooting; check cables and termination. |
501Failure | Mix->Main CAN t/oCAN communication lost between the main board and a module (gas console GCC, torch console TCC, chopper Ch). | Follow the manual’s CAN troubleshooting; check cables and termination. |
503Failure | TCC->Main CAN t/oCAN communication lost between the main board and a module (gas console GCC, torch console TCC, chopper Ch). | Follow the manual’s CAN troubleshooting; check cables and termination. |
504Failure | Ch1->Main CAN t/oCAN communication lost between the main board and a module (gas console GCC, torch console TCC, chopper Ch). | Follow the manual’s CAN troubleshooting; check cables and termination. |
505Failure | Ch2->Main CAN t/oCAN communication lost between the main board and a module (gas console GCC, torch console TCC, chopper Ch). | Follow the manual’s CAN troubleshooting; check cables and termination. |
507Failure | Main no CANCAN communication lost between the main board and a module (gas console GCC, torch console TCC, chopper Ch). | Follow the manual’s CAN troubleshooting; check cables and termination. |
508Error | CAN BusyCAN communication lost between the main board and a module (gas console GCC, torch console TCC, chopper Ch). | Follow the manual’s CAN troubleshooting; check cables and termination. |
510Failure | Main->GCC CAN t/oCAN communication lost between the main board and a module (gas console GCC, torch console TCC, chopper Ch). | Follow the manual’s CAN troubleshooting; check cables and termination. |
511Failure | Main->Mix CAN t/oCAN communication lost between the main board and a module (gas console GCC, torch console TCC, chopper Ch). | Follow the manual’s CAN troubleshooting; check cables and termination. |
513Failure | Main->TCC CAN t/oCAN communication lost between the main board and a module (gas console GCC, torch console TCC, chopper Ch). | Follow the manual’s CAN troubleshooting; check cables and termination. |
514Failure | Main->Ch1 CAN t/oCAN communication lost between the main board and a module (gas console GCC, torch console TCC, chopper Ch). | Follow the manual’s CAN troubleshooting; check cables and termination. |
515Failure | Main->Ch2 CAN t/oCAN communication lost between the main board and a module (gas console GCC, torch console TCC, chopper Ch). | Follow the manual’s CAN troubleshooting; check cables and termination. |
520Alert | Ignite t/o (no pilot arc)Ignition: no pilot arc, no arc transfer, or high frequency on too long. | Check consumables, pierce height, ground and gas. |
521Alert | Pilot arc t/o (no arc transfer)Ignition: no pilot arc, no arc transfer, or high frequency on too long. | Check consumables, pierce height, ground and gas. |
522Alert | Preflow t/oTimeout during a gas step (preflow, purge). | Check pressures and leaks (manual procedure). |
523Error | Preflow purge t/oTimeout during a gas step (preflow, purge). | Check pressures and leaks (manual procedure). |
524Error | Cutflow purge t/oTimeout during a gas step (preflow, purge). | Check pressures and leaks (manual procedure). |
525Error | Inert gas purge t/oTimeout during a gas step (preflow, purge). | Check pressures and leaks (manual procedure). |
530Alert | Low psi–Line AGas or water pressure out of range (console inlet or outlet). | Set supply pressures per the process; check regulators and lines. |
531Alert | Low psi–Line BGas or water pressure out of range (console inlet or outlet). | Set supply pressures per the process; check regulators and lines. |
532Alert | Low psi–H2OGas or water pressure out of range (console inlet or outlet). | Set supply pressures per the process; check regulators and lines. |
533Alert | Low psi–F5Gas or water pressure out of range (console inlet or outlet). | Set supply pressures per the process; check regulators and lines. |
534Alert | Low psi–ShieldGas or water pressure out of range (console inlet or outlet). | Set supply pressures per the process; check regulators and lines. |
540Error | Low flow 1–CoolantCoolant: flow too low or too high, or level low. | Fill the reservoir; check filter, pump and lines. |
542Failure | Low flow–CoolantCoolant: flow too low or too high, or level low. | Fill the reservoir; check filter, pump and lines. |
543Error | High flow 1–CoolantCoolant: flow too low or too high, or level low. | Fill the reservoir; check filter, pump and lines. |
544Failure | High flow–CoolantCoolant: flow too low or too high, or level low. | Fill the reservoir; check filter, pump and lines. |
550Alert | No plasma arcIgnition: no pilot arc, no arc transfer, or high frequency on too long. | Check consumables, pierce height, ground and gas. |
552Alert | DC below limit–Ch1Abnormal chopper current (none, too low, too high, present at idle); often worn consumables. | Inspect and replace consumables; follow the manual’s chopper-current procedure. |
553Alert | DC below limit–Ch2Abnormal chopper current (none, too low, too high, present at idle); often worn consumables. | Inspect and replace consumables; follow the manual’s chopper-current procedure. |
555Failure | DC exceeds limit–Ch1Abnormal chopper current (none, too low, too high, present at idle); often worn consumables. | Inspect and replace consumables; follow the manual’s chopper-current procedure. |
556Failure | DC exceeds limit–Ch2Abnormal chopper current (none, too low, too high, present at idle); often worn consumables. | Inspect and replace consumables; follow the manual’s chopper-current procedure. |
560Error | Over temp–Ch1Component over-temperature (chopper, inductor, transformer, coolant). | Check ventilation, fans, coolant and heat-sink cleanliness. |
561Error | Over temp–Ch2Component over-temperature (chopper, inductor, transformer, coolant). | Check ventilation, fans, coolant and heat-sink cleanliness. |
570Alert | Start on powerupStart signal on at power-up, or removed during a step. | Check the CNC start signal. |
571Alert | Start on wait-startStart signal on at power-up, or removed during a step. | Check the CNC start signal. |
574Info | Start removed preflowStart signal on at power-up, or removed during a step. | Check the CNC start signal. |
575Info | Start removed igniteStart signal on at power-up, or removed during a step. | Check the CNC start signal. |
576Info | Start removed pilotStart signal on at power-up, or removed during a step. | Check the CNC start signal. |
577Info | Start removed ramp upStart signal on at power-up, or removed during a step. | Check the CNC start signal. |
580Error | Over temp–Ind 1Component over-temperature (chopper, inductor, transformer, coolant). | Check ventilation, fans, coolant and heat-sink cleanliness. |
581Error | Over temp–Ind 2Component over-temperature (chopper, inductor, transformer, coolant). | Check ventilation, fans, coolant and heat-sink cleanliness. |
582Error | Over temp–Ind 3Component over-temperature (chopper, inductor, transformer, coolant). | Check ventilation, fans, coolant and heat-sink cleanliness. |
583Error | Over temp–Ind 4Component over-temperature (chopper, inductor, transformer, coolant). | Check ventilation, fans, coolant and heat-sink cleanliness. |
586Error | Over temp–XfmrComponent over-temperature (chopper, inductor, transformer, coolant). | Check ventilation, fans, coolant and heat-sink cleanliness. |
587Error | Over temp–CoolantComponent over-temperature (chopper, inductor, transformer, coolant). | Check ventilation, fans, coolant and heat-sink cleanliness. |
600Error | No TCC foundCAN communication lost between the main board and a module (gas console GCC, torch console TCC, chopper Ch). | Follow the manual’s CAN troubleshooting; check cables and termination. |
601Error | No Chopper 1 foundCAN communication lost between the main board and a module (gas console GCC, torch console TCC, chopper Ch). | Follow the manual’s CAN troubleshooting; check cables and termination. |
602Error | No GCC foundCAN communication lost between the main board and a module (gas console GCC, torch console TCC, chopper Ch). | Follow the manual’s CAN troubleshooting; check cables and termination. |
604Alert | No Chopper 2 foundCAN communication lost between the main board and a module (gas console GCC, torch console TCC, chopper Ch). | Follow the manual’s CAN troubleshooting; check cables and termination. |
610Failure | Ch1 Torch Protect ChAAbnormal chopper current (none, too low, too high, present at idle); often worn consumables. | Inspect and replace consumables; follow the manual’s chopper-current procedure. |
611Failure | Ch1 Torch Protect ChBAbnormal chopper current (none, too low, too high, present at idle); often worn consumables. | Inspect and replace consumables; follow the manual’s chopper-current procedure. |
612Failure | Ch2 Torch Protect ChAAbnormal chopper current (none, too low, too high, present at idle); often worn consumables. | Inspect and replace consumables; follow the manual’s chopper-current procedure. |
613Failure | Ch2 Torch Protect ChBAbnormal chopper current (none, too low, too high, present at idle); often worn consumables. | Inspect and replace consumables; follow the manual’s chopper-current procedure. |
620Alert | Arc stretch detectedArc stretch detected at the end of cut (ramp-down). | Check the end-of-cut sequence and height. |
621Failure | Over voltage–DC busAbnormal voltage (DC bus, 15 V, 24 V) or phase fault. | Check input power; follow the manual procedure. |
622Failure | Under voltage–DC busAbnormal voltage (DC bus, 15 V, 24 V) or phase fault. | Check input power; follow the manual procedure. |
623Error | Ch1 DC at idleAbnormal chopper current (none, too low, too high, present at idle); often worn consumables. | Inspect and replace consumables; follow the manual’s chopper-current procedure. |
624Error | Ch2 DC at idleAbnormal chopper current (none, too low, too high, present at idle); often worn consumables. | Inspect and replace consumables; follow the manual’s chopper-current procedure. |
626Alert | No DC output–Ch1Abnormal chopper current (none, too low, too high, present at idle); often worn consumables. | Inspect and replace consumables; follow the manual’s chopper-current procedure. |
627Alert | No DC output–Ch2Abnormal chopper current (none, too low, too high, present at idle); often worn consumables. | Inspect and replace consumables; follow the manual’s chopper-current procedure. |
631Failure | DC at wait-startAbnormal chopper current (none, too low, too high, present at idle); often worn consumables. | Inspect and replace consumables; follow the manual’s chopper-current procedure. |
640Info | No errorSystem, process, firmware or communication information (see the manual). | Follow the manual’s action; keep firmware current. |
642Info | System poweredSystem, process, firmware or communication information (see the manual). | Follow the manual’s action; keep firmware current. |
643Info | No process loadedSystem, process, firmware or communication information (see the manual). | Follow the manual’s action; keep firmware current. |
645Info | System is offSystem, process, firmware or communication information (see the manual). | Follow the manual’s action; keep firmware current. |
646Info | System turned offSystem, process, firmware or communication information (see the manual). | Follow the manual’s action; keep firmware current. |
647Info | Process selectedSystem, process, firmware or communication information (see the manual). | Follow the manual’s action; keep firmware current. |
648Info | Manual modeSystem, process, firmware or communication information (see the manual). | Follow the manual’s action; keep firmware current. |
651Alert | HF timeoutIgnition: no pilot arc, no arc transfer, or high frequency on too long. | Check consumables, pierce height, ground and gas. |
652Error | Block def over limitSystem, process, firmware or communication information (see the manual). | Follow the manual’s action; keep firmware current. |
653Error | Block time over limitSystem, process, firmware or communication information (see the manual). | Follow the manual’s action; keep firmware current. |
654Error | Ch1 ArcOn TimeoutIgnition: no pilot arc, no arc transfer, or high frequency on too long. | Check consumables, pierce height, ground and gas. |
655Alert | Current (DC) during preflowAbnormal chopper current (none, too low, too high, present at idle); often worn consumables. | Inspect and replace consumables; follow the manual’s chopper-current procedure. |
656Error | Default caseSystem, process, firmware or communication information (see the manual). | Follow the manual’s action; keep firmware current. |
657Error | Bad block typeSystem, process, firmware or communication information (see the manual). | Follow the manual’s action; keep firmware current. |
658Alert | Block def under limitSystem, process, firmware or communication information (see the manual). | Follow the manual’s action; keep firmware current. |
660Error | Thermistor Fault–Ind 1Thermistor missing or faulty (temperature sensing). | Measure the thermistor resistance with a multimeter; check the connector. |
661Error | Thermistor Fault–Ind 2Thermistor missing or faulty (temperature sensing). | Measure the thermistor resistance with a multimeter; check the connector. |
662Error | Thermistor Fault–Ind 3Thermistor missing or faulty (temperature sensing). | Measure the thermistor resistance with a multimeter; check the connector. |
663Error | Thermistor Fault–Ind 4Thermistor missing or faulty (temperature sensing). | Measure the thermistor resistance with a multimeter; check the connector. |
666Error | Thermistor Fault–XfmrThermistor missing or faulty (temperature sensing). | Measure the thermistor resistance with a multimeter; check the connector. |
667Error | Thermistor Fault–Ch1Thermistor missing or faulty (temperature sensing). | Measure the thermistor resistance with a multimeter; check the connector. |
668Error | Thermistor Fault–Ch2Thermistor missing or faulty (temperature sensing). | Measure the thermistor resistance with a multimeter; check the connector. |
670Error | Thermistor Fault–CoolantThermistor missing or faulty (temperature sensing). | Measure the thermistor resistance with a multimeter; check the connector. |
671Error | No Thermistor–Ind 1Thermistor missing or faulty (temperature sensing). | Measure the thermistor resistance with a multimeter; check the connector. |
672Error | No Thermistor–Ind 2Thermistor missing or faulty (temperature sensing). | Measure the thermistor resistance with a multimeter; check the connector. |
673Error | No Thermistor–Ind 3Thermistor missing or faulty (temperature sensing). | Measure the thermistor resistance with a multimeter; check the connector. |
674Error | No Thermistor–Ind 4Thermistor missing or faulty (temperature sensing). | Measure the thermistor resistance with a multimeter; check the connector. |
677Error | No Thermistor–XfmrThermistor missing or faulty (temperature sensing). | Measure the thermistor resistance with a multimeter; check the connector. |
678Error | No Thermistor–Ch1Thermistor missing or faulty (temperature sensing). | Measure the thermistor resistance with a multimeter; check the connector. |
679Error | No Thermistor–Ch2Thermistor missing or faulty (temperature sensing). | Measure the thermistor resistance with a multimeter; check the connector. |
681Error | No Thermistor–CoolantThermistor missing or faulty (temperature sensing). | Measure the thermistor resistance with a multimeter; check the connector. |
691Error | Node resetSystem, process, firmware or communication information (see the manual). | Follow the manual’s action; keep firmware current. |
695Alert | Low inlet H2 -Mix ( OptiMix™ only)Gas or water pressure out of range (console inlet or outlet). | Set supply pressures per the process; check regulators and lines. |
696Alert | Low inlet Ar-Mix ( OptiMix only)Gas or water pressure out of range (console inlet or outlet). | Set supply pressures per the process; check regulators and lines. |
697Alert | Low inlet N2 -Mix ( OptiMix only)Gas or water pressure out of range (console inlet or outlet). | Set supply pressures per the process; check regulators and lines. |
699Error | Mix Fault ( OptiMix only)Gas console fault (solenoid valve, pressure sensor, OptiMix mixer). | Manual procedure for the named part. |
700Alert | Gas Inlet F5–GCC ( VWI™ or OptiMix only)Gas or water pressure out of range (console inlet or outlet). | Set supply pressures per the process; check regulators and lines. |
701Alert | Low Inlet H2O–GCC ( VWI or OptiMix only)Gas or water pressure out of range (console inlet or outlet). | Set supply pressures per the process; check regulators and lines. |
702Alert | Shield Gas Inlet N2 –TCCGas or water pressure out of range (console inlet or outlet). | Set supply pressures per the process; check regulators and lines. |
703Alert | Shield Gas Inlet O2 –TCCGas or water pressure out of range (console inlet or outlet). | Set supply pressures per the process; check regulators and lines. |
704Alert | Shield Gas Inlet Air–TCCGas or water pressure out of range (console inlet or outlet). | Set supply pressures per the process; check regulators and lines. |
705Alert | Shield Gas Inlet Ar–TCCGas or water pressure out of range (console inlet or outlet). | Set supply pressures per the process; check regulators and lines. |
706Error | No sensor P1–TCCGas console fault (solenoid valve, pressure sensor, OptiMix mixer). | Manual procedure for the named part. |
707Error | No sensor P2–TCCGas console fault (solenoid valve, pressure sensor, OptiMix mixer). | Manual procedure for the named part. |
708Error | No sensor P3–TCCGas console fault (solenoid valve, pressure sensor, OptiMix mixer). | Manual procedure for the named part. |
709Error | No sensor P4–TCCGas console fault (solenoid valve, pressure sensor, OptiMix mixer). | Manual procedure for the named part. |
710Error | No sensor P5–TCCGas console fault (solenoid valve, pressure sensor, OptiMix mixer). | Manual procedure for the named part. |
711Error | No sensor P14–TCCGas console fault (solenoid valve, pressure sensor, OptiMix mixer). | Manual procedure for the named part. |
712Error | No sensor P6–GCC ( VWI or OptiMix only)Gas console fault (solenoid valve, pressure sensor, OptiMix mixer). | Manual procedure for the named part. |
713Error | No sensor P7–GCC ( VWI or OptiMix only)Gas console fault (solenoid valve, pressure sensor, OptiMix mixer). | Manual procedure for the named part. |
714Error | No sensor P8–GCC ( VWI or OptiMix only)Gas console fault (solenoid valve, pressure sensor, OptiMix mixer). | Manual procedure for the named part. |
715Error | No sensor P9–GCCGas console fault (solenoid valve, pressure sensor, OptiMix mixer). | Manual procedure for the named part. |
716Alert | Set process deniedSystem, process, firmware or communication information (see the manual). | Follow the manual’s action; keep firmware current. |
717Alert | Low voltage–mix ( OptiMix only)Abnormal voltage (DC bus, 15 V, 24 V) or phase fault. | Check input power; follow the manual procedure. |
718Alert | High voltage–mix ( OptiMix only)Abnormal voltage (DC bus, 15 V, 24 V) or phase fault. | Check input power; follow the manual procedure. |
719Alert | Mix pwm 100% ( OptiMix only)Gas console fault (solenoid valve, pressure sensor, OptiMix mixer). | Manual procedure for the named part. |
720Alert | Mix P21>Pin ( OptiMix only)Gas console fault (solenoid valve, pressure sensor, OptiMix mixer). | Manual procedure for the named part. |
721Error | Mix checksum ( OptiMix only)Gas console fault (solenoid valve, pressure sensor, OptiMix mixer). | Manual procedure for the named part. |
722Error | Mix flow cal ( OptiMix only)Gas console fault (solenoid valve, pressure sensor, OptiMix mixer). | Manual procedure for the named part. |
723Error | Mix pressure cal ( OptiMix only)Gas console fault (solenoid valve, pressure sensor, OptiMix mixer). | Manual procedure for the named part. |
724Error | Mix I2C1 ( OptiMix only)Gas console fault (solenoid valve, pressure sensor, OptiMix mixer). | Manual procedure for the named part. |
725Error | Mix I2C2 ( OptiMix only)Gas console fault (solenoid valve, pressure sensor, OptiMix mixer). | Manual procedure for the named part. |
726Error | Mix system clock ( OptiMix only)Gas console fault (solenoid valve, pressure sensor, OptiMix mixer). | Manual procedure for the named part. |
730Alert | Solenoid error V1Gas console fault (solenoid valve, pressure sensor, OptiMix mixer). | Manual procedure for the named part. |
733Alert | Solenoid error V4Gas console fault (solenoid valve, pressure sensor, OptiMix mixer). | Manual procedure for the named part. |
734Alert | Solenoid error V5Gas console fault (solenoid valve, pressure sensor, OptiMix mixer). | Manual procedure for the named part. |
735Alert | Solenoid error V6Gas console fault (solenoid valve, pressure sensor, OptiMix mixer). | Manual procedure for the named part. |
736Alert | Solenoid error V7Gas console fault (solenoid valve, pressure sensor, OptiMix mixer). | Manual procedure for the named part. |
737Alert | Solenoid error V8Gas console fault (solenoid valve, pressure sensor, OptiMix mixer). | Manual procedure for the named part. |
738Alert | Solenoid error V9Gas console fault (solenoid valve, pressure sensor, OptiMix mixer). | Manual procedure for the named part. |
739Alert | Solenoid error V10Gas console fault (solenoid valve, pressure sensor, OptiMix mixer). | Manual procedure for the named part. |
740Alert | Solenoid error V11Gas console fault (solenoid valve, pressure sensor, OptiMix mixer). | Manual procedure for the named part. |
741Alert | Solenoid error V12Gas console fault (solenoid valve, pressure sensor, OptiMix mixer). | Manual procedure for the named part. |
742Alert | Mix I2C1 Alert ( OptiMix only)Gas console fault (solenoid valve, pressure sensor, OptiMix mixer). | Manual procedure for the named part. |
743Alert | Mix I2C2 Alert ( OptiMix only)Gas console fault (solenoid valve, pressure sensor, OptiMix mixer). | Manual procedure for the named part. |
744Alert | Low Speed–MagFan 1Fan running too slow. | Clean or replace the fan. |
745Alert | Low Speed–MagFan 2Fan running too slow. | Clean or replace the fan. |
748Alert | Low Speed–HxFan 1Fan running too slow. | Clean or replace the fan. |
749Alert | Low Speed–HxFan 2Fan running too slow. | Clean or replace the fan. |
750Alert | Low Speed–CtrlFan 1Fan running too slow. | Clean or replace the fan. |
751Alert | Low Speed–CtrlFan 2Fan running too slow. | Clean or replace the fan. |
752Error | Phase Fault–Ch1Abnormal voltage (DC bus, 15 V, 24 V) or phase fault. | Check input power; follow the manual procedure. |
753Error | Phase Fault–Ch2Abnormal voltage (DC bus, 15 V, 24 V) or phase fault. | Check input power; follow the manual procedure. |
755Alert | Low level–CoolantCoolant: flow too low or too high, or level low. | Fill the reservoir; check filter, pump and lines. |
756Info | Leak test resultsSystem, process, firmware or communication information (see the manual). | Follow the manual’s action; keep firmware current. |
757Alert | DC work exceeds limitAbnormal chopper current (none, too low, too high, present at idle); often worn consumables. | Inspect and replace consumables; follow the manual’s chopper-current procedure. |
758Error | Main 24V dipAbnormal voltage (DC bus, 15 V, 24 V) or phase fault. | Check input power; follow the manual procedure. |
759Alert | GCC 24V bus lowAbnormal voltage (DC bus, 15 V, 24 V) or phase fault. | Check input power; follow the manual procedure. |
768Alert | Gas Inlet – O2 Line AGas or water pressure out of range (console inlet or outlet). | Set supply pressures per the process; check regulators and lines. |
769Alert | Gas Inlet – Argon Line BGas or water pressure out of range (console inlet or outlet). | Set supply pressures per the process; check regulators and lines. |
770Alert | Gas Inlet – N2 Line BGas or water pressure out of range (console inlet or outlet). | Set supply pressures per the process; check regulators and lines. |
771Alert | Gas Inlet – Air Line AGas or water pressure out of range (console inlet or outlet). | Set supply pressures per the process; check regulators and lines. |
772Alert | High inlet line AGas or water pressure out of range (console inlet or outlet). | Set supply pressures per the process; check regulators and lines. |
774Alert | P5 >= P2Gas or water pressure out of range (console inlet or outlet). | Set supply pressures per the process; check regulators and lines. |
775Alert | Node updateSystem, process, firmware or communication information (see the manual). | Follow the manual’s action; keep firmware current. |
779Error | Ch1 15V busAbnormal voltage (DC bus, 15 V, 24 V) or phase fault. | Check input power; follow the manual procedure. |
780Error | Ch2 15V busAbnormal voltage (DC bus, 15 V, 24 V) or phase fault. | Check input power; follow the manual procedure. |
782Alert | Low psi–P2Gas or water pressure out of range (console inlet or outlet). | Set supply pressures per the process; check regulators and lines. |
784Error | Main 24V highAbnormal voltage (DC bus, 15 V, 24 V) or phase fault. | Check input power; follow the manual procedure. |
789Alert | Fieldbus faultSystem, process, firmware or communication information (see the manual). | Follow the manual’s action; keep firmware current. |
791Error | No Thermistor–Con XfmrThermistor missing or faulty (temperature sensing). | Measure the thermistor resistance with a multimeter; check the connector. |
792Error | Thermistor Fault–Con XfmrThermistor missing or faulty (temperature sensing). | Measure the thermistor resistance with a multimeter; check the connector. |
793Error | Over temp–Con XfmrComponent over-temperature (chopper, inductor, transformer, coolant). | Check ventilation, fans, coolant and heat-sink cleanliness. |
794Alert | No MAC foundSystem, process, firmware or communication information (see the manual). | Follow the manual’s action; keep firmware current. |
797Error | Firmware Version MismatchSystem, process, firmware or communication information (see the manual). | Follow the manual’s action; keep firmware current. |
798Info | USB firmware updateSystem, process, firmware or communication information (see the manual). | Follow the manual’s action; keep firmware current. |
799Alert | Remote-switch mismatchSystem, process, firmware or communication information (see the manual). | Follow the manual’s action; keep firmware current. |
Source: Hypertherm — XPR300 Instruction Manual, tableau « Diagnostic codes » (version en ligne) · consulted November 26, 2026
Hypertherm — EDGE Connect / Phoenix software 37
CNC errors carry a number (Error 1, Error 8…); faults show by name. The manual details causes and actions for each.
| Code | Meaning | What to check |
|---|---|---|
Fast Stop Active | Fast stop input active: motion stopped. | See “CNC fault message reference” in the manual. |
HPR Fault | The HPR plasma system reports a fault. | See “CNC fault message reference” in the manual. |
Cut Gas Lost | Cut gas lost while cutting. | See “CNC fault message reference” in the manual. |
Cut Sense Lost | Cut sense (arc transfer) signal lost while cutting. | See “CNC fault message reference” in the manual. |
Invalid Process Requested in Part Program | The part program asks for a process the plasma system does not know. | See “CNC fault message reference” in the manual. |
Remote Pause Active | Remote pause input active. | See “CNC fault message reference” in the manual. |
Safety Mat Active | Safety mat active. | See “CNC fault message reference” in the manual. |
Software Limit Active | Software limit reached. | See “CNC fault message reference” in the manual. |
Torch Collision | Torch collision sensor tripped. | See “CNC fault message reference” in the manual. |
Field Bus Drives Not Ready | Fieldbus drives not ready. | See “CNC fault message reference” in the manual. |
Error 1 | Transverse Position ErrorThe transverse axis lags the commanded position by more than the servo error tolerance (mechanical bind, drive fault; on new installs: tolerance, gains, speed or acceleration set wrong). | See “CNC error message reference” in the manual (causes and actions per error). |
Error 2 | Rail Position ErrorSame following error on the rail axis. | See “CNC error message reference” in the manual (causes and actions per error). |
Error 3 | Dual Gantry Position ErrorFollowing error on the dual-gantry axis. | See “CNC error message reference” in the manual (causes and actions per error). |
Error 4 | Rotate Position ErrorFollowing error on the rotate axis. | See “CNC error message reference” in the manual (causes and actions per error). |
Error 5 | Tilt Position ErrorFollowing error on the tilt axis. | See “CNC error message reference” in the manual (causes and actions per error). |
Error 6 | CBH Position ErrorFollowing error on the CBH axis. | See “CNC error message reference” in the manual (causes and actions per error). |
Error 7 | THC Position ErrorFollowing error on the torch lifter (bind, drive, torque limit, settings too low or high). | See “CNC error message reference” in the manual (causes and actions per error). |
Error 8 / 9 | Transverse / Rail Positive Hardware OvertravelPositive hardware overtravel (transverse / rail): switch engaged or faulty, wiring, or table powered off. | See “CNC error message reference” in the manual (causes and actions per error). |
Error 13 / 14 | Transverse / Rail Negative Hardware OvertravelNegative hardware overtravel reached. | See “CNC error message reference” in the manual (causes and actions per error). |
Error 18 / 19 | Transverse / Rail Positive Software OvertravelPositive software overtravel reached. | See “CNC error message reference” in the manual (causes and actions per error). |
Error 23 / 24 | Transverse / Rail Negative Software OvertravelNegative software overtravel reached. | See “CNC error message reference” in the manual (causes and actions per error). |
Error 28 – 31 | Tilt Hardware / Software OvertravelTilt axis overtravels (hardware 28–29, software 30–31). | See “CNC error message reference” in the manual (causes and actions per error). |
Error 34 / 35 | Rotate Positive / Negative Software OvertravelRotate axis software overtravels. | See “CNC error message reference” in the manual (causes and actions per error). |
Error 36 | Dual Gantry Skew ErrorSkew error between the two gantry sides. | See “CNC error message reference” in the manual (causes and actions per error). |
Error 37 | Collision FaultCollision fault. | See “CNC error message reference” in the manual (causes and actions per error). |
Error 38 | Excessive Mechanical SkewExcessive mechanical skew of the gantry. | See “CNC error message reference” in the manual (causes and actions per error). |
Error 41 | Dual Head Collision FaultCollision between two heads. | See “CNC error message reference” in the manual (causes and actions per error). |
Error 42 | Torch CollisionTorch collision. | See “CNC error message reference” in the manual (causes and actions per error). |
Error 44 | Hardware Fault or FailureHardware fault or failure. | See “CNC error message reference” in the manual (causes and actions per error). |
Error 45 – 48 | Dual Transverse OvertravelsDual transverse axis overtravels. | See “CNC error message reference” in the manual (causes and actions per error). |
Error 60 | Field Bus Configuration FaultFieldbus configuration fault. | See “CNC error message reference” in the manual (causes and actions per error). |
Error 61 | Field Bus Device FaultFieldbus device fault. | See “CNC error message reference” in the manual (causes and actions per error). |
Error 62 | Field Bus Network FaultFieldbus network fault. | See “CNC error message reference” in the manual (causes and actions per error). |
Error 64 | Field Bus Slave FaultFieldbus slave fault. | See “CNC error message reference” in the manual (causes and actions per error). |
Error 66 | RTOS Watchdog FaultReal-time OS watchdog fault. | See “CNC error message reference” in the manual (causes and actions per error). |
Error 67 / 68 | PLC application / PLCPLC application or PLC fault. | See “CNC error message reference” in the manual (causes and actions per error). |
Error 18 · 19 · 54 · 55 (HASP) | HASP key ID not found / invalid update data / update too old / update too newHASP licence key errors during a feature update. | See “CNC error message reference” in the manual (causes and actions per error). |
Source: Hypertherm — EDGE Connect Installation and Setup Manual (809340, rév. 4, nov. 2020; copie publique d’un distributeur) · consulted November 26, 2026
ESAB — Cutmaster 40 and Cutmaster 60i 19
The two models use different codes: check the rating plate.
| Code | Meaning | What to check |
|---|---|---|
HI | Over Temp (Cutmaster 40)Heatsink or transformer over-temperature. | Let it cool; respect the duty cycle. |
PIP | Parts In Place (Cutmaster 40)Shield cup removed. | Refit and tighten the shield cup. |
PIC | Parts In Contact (Cutmaster 40)Tip not touching the electrode at start-up (often tip missing). | Install tip and electrode. |
SCC | Trigger Fault (Cutmaster 40)Trigger pulled at start-up or while a fault clears. | Release the trigger. |
LoP | Gas Fault (Cutmaster 40)Consumables do not separate when gas flows (gas not connected or pressure too high). | Connect gas; set inlet to 120 psi. |
E02 | Bus Fault (Cutmaster 40)Bus voltage below about 360 V. | Authorized service center. |
E03 | Bias Fault (Cutmaster 40)Bias voltage below about 13.5 V. | Authorized service center. |
E06 | Low Line Voltage (Cutmaster 40)Input voltage too low. | Check input power. |
E07 | High Line Voltage (Cutmaster 40)Input voltage too high. | Check input power. |
E001 | Over Temp (Cutmaster 60i)Ambient too hot, duty cycle exceeded, fan or internal fault. | Let it cool; check the fan. |
E002 | Input Fault (Cutmaster 60i)Input voltage out of range or low bus; 1/3-phase jumpers J300 set wrong. | Check the line and jumpers. |
E004 | PIP Fault (Cutmaster 60i)Shield cup missing or loose. | Tighten the cup; otherwise torch and leads. |
E005 | PIC Fault (Cutmaster 60i)Tip, start cartridge or electrode missing or worn; inlet pressure too high. | Check consumables and pressure. |
E009 | Fan Fault (Cutmaster 60i)Fan failed or disconnected. | Authorized service center. |
E010 | Low Output Current (Cutmaster 60i)Work current below setting (shorted pilot switch or current sensor). | Authorized service center. |
E012 | Output Fault (Cutmaster 60i)Tip-to-electrode voltage too low: consumables not separating, stuck cartridge, shorted torch. | Power off, bleed pressure, check the start cartridge. |
E014 | Trigger Fault (Cutmaster 60i)Trigger (start signal) active at start-up. | Release the trigger or CNC signal. |
E016 | Pressure Fault (Cutmaster 60i)Air pressure too low for the selected settings. | Increase supply pressure. |
E024 / E031 | Internal Error (Cutmaster 60i)Internal error (fault lights flashing). | Turn off and on; if persistent, service. |
Sources: ESAB — CUTMASTER 40 Operating Manual (0-5557); ESAB — CUTMASTER 60i Operating Manual (0-5562, rév. AA, 2019) · consulted November 26, 2026
Lincoln Electric — Tomahawk 1000 (status lights) 6
The Tomahawk 1000 shows no numbers: it reports faults with steady or blinking lights.
| Code | Meaning | What to check |
|---|---|---|
Vert clignotant · green blinking | Input voltage out of range; restarts by itself when voltage returns. | Check input power. |
Rouge clignotant · red blinking | Internal auxiliary undervoltage. | Turn off then on. |
Jaune thermique · yellow thermal | Overheated, output disabled (duty cycle exceeded). | Leave on to cool. |
Jaune pression · yellow gas pressure | Gas pressure out of range; automatic 10 s purge to adjust. | Adjust pressure during the purge. |
Jaune PIP · yellow PIP | Consumables not installed correctly (shield cup). | Hand-tighten the cup, not too hard; restarts after 5 s. |
Vert fixe + rouge et jaune clignotants · green on + red and yellow blinking | Pilot arc did not transfer within 4 s; stopped to protect the torch. | Release the trigger and try again. |
Source: Lincoln Electric — Tomahawk 1000 Operator’s Manual (IM10026-A; copie publique) · consulted November 26, 2026
Fiber laser
FSCUT / Bochu — BCS100 height controller (CypCut) 10
Alarms shown by the BCS100 (capacitive height control). The history keeps the last 20 (Alarm information menu).
| Code | Meaning | What to check |
|---|---|---|
Z+/Z- limit enable | Z+ or Z- limit input active (object detected, dirty or broken sensor, logic or wiring). | Clean or replace the sensor; check “Limit logic” and wiring. |
Out of Z range | Z moved beyond the configured range. | Check the range parameter, homing and encoder. |
Servo alarm | Servo alarm input (ALM) active. | Read the servo alarm; check “Servo Type”, wiring, noise. |
Encoder moves abnormally | Encoder position changes at standstill (vibration, low servo stiffness, noise). | Shield and ground the encoder cable; add ferrites. |
Encoder no response | Servo gets a command but the encoder does not change. | Check wiring and servo speed mode. |
Encoder deviation large | Too large a gap between target and actual position. | Check encoder direction, wiring, mechanical binding. |
Capacity is 0 | Nozzle capacitance not measured: nozzle on the sheet, water in the head, bad preamplifier, short. | Check nozzle, head, preamplifier and connections. |
Local capacity small | Local capacitance too small (parts moved, heat, calibration). | Recalibrate (15 mm recommended in 2D). |
Hit board over time | Calibration: the head moves down without touching the sheet. | Place the head about 5 mm above the sheet and retry. |
Following error too large | Following error beyond the set threshold. | Review the threshold and alarm filter (Alarm settings menu). |
Source: FSCUT (Bochu) — BCS100 Capacitive Height Controller User Manual V3.22 · consulted November 26, 2026
Raytools — BM110 head (focus servo) 1
| Code | Meaning | What to check |
|---|---|---|
Er_020 | The focus servo trips its protection when following error reaches ±6000. | Check power and encoder cables and limits; power-cycle to clear. |
Source: Raytools — BM110 3.3 kW Auto Focus Laser Cutting Head User Manual V2.0 (section 5.4) · consulted November 26, 2026
Routers and PC controllers
Grbl — Grbl 1.1 (hobby routers and lasers, UGS, LightBurn) 46
Grbl 1.1 returns “ALARM:n” or “error:n”. After a limit alarm or a stop while moving, re-home ($H).
| Code | Meaning | What to check |
|---|---|---|
ALARM:1 | Hard limitHard limit has been triggered. Machine position is likely lost due to sudden halt. Re-homing is highly recommended. | Read the message, fix, then $X (unlock) or $H (home). |
ALARM:2 | Soft limitSoft limit alarm. G-code motion target exceeds machine travel. Machine position retained. Alarm may be safely unlocked. | Read the message, fix, then $X (unlock) or $H (home). |
ALARM:3 | Abort during cycleReset while in motion. Machine position is likely lost due to sudden halt. Re-homing is highly recommended. | Read the message, fix, then $X (unlock) or $H (home). |
ALARM:4 | Probe failProbe fail. Probe is not in the expected initial state before starting probe cycle when G38.2 and G38.3 is not triggered and G38.4 and G38.5 is triggered. | Read the message, fix, then $X (unlock) or $H (home). |
ALARM:5 | Probe failProbe fail. Probe did not contact the workpiece within the programmed travel for G38.2 and G38.4. | Read the message, fix, then $X (unlock) or $H (home). |
ALARM:6 | Homing failHoming fail. The active homing cycle was reset. | Read the message, fix, then $X (unlock) or $H (home). |
ALARM:7 | Homing failHoming fail. Safety door was opened during homing cycle. | Read the message, fix, then $X (unlock) or $H (home). |
ALARM:8 | Homing failHoming fail. Pull off travel failed to clear limit switch. Try increasing pull-off setting or check wiring. | Read the message, fix, then $X (unlock) or $H (home). |
ALARM:9 | Homing failHoming fail. Could not find limit switch within search distances. Try increasing max travel, decreasing pull-off distance, or check wiring. | Read the message, fix, then $X (unlock) or $H (home). |
ALARM:10 | Homing failHoming fail. Second dual axis limit switch failed to trigger within configured search distance after first. Try increasing trigger fail distance or check wiring. | Read the message, fix, then $X (unlock) or $H (home). |
error:1 | Expected command letterG-code words consist of a letter and a value. Letter was not found. | Fix the line (often the post processor) or the named setting. |
error:2 | Bad number formatMissing the expected G-code word value or numeric value format is not valid. | Fix the line (often the post processor) or the named setting. |
error:3 | Invalid statementGrbl '$' system command was not recognized or supported. | Fix the line (often the post processor) or the named setting. |
error:4 | Value < 0Negative value received for an expected positive value. | Fix the line (often the post processor) or the named setting. |
error:5 | Setting disabledHoming cycle failure. Homing is not enabled via settings. | Fix the line (often the post processor) or the named setting. |
error:6 | Value < 3 usecMinimum step pulse time must be greater than 3usec. | Fix the line (often the post processor) or the named setting. |
error:7 | EEPROM read fail. Using defaultsAn EEPROM read failed. Auto-restoring affected EEPROM to default values. | Fix the line (often the post processor) or the named setting. |
error:8 | Not idleGrbl '$' command cannot be used unless Grbl is IDLE. Ensures smooth operation during a job. | Fix the line (often the post processor) or the named setting. |
error:9 | G-code lockG-code commands are locked out during alarm or jog state. | Fix the line (often the post processor) or the named setting. |
error:10 | Homing not enabledSoft limits cannot be enabled without homing also enabled. | Fix the line (often the post processor) or the named setting. |
error:11 | Line overflowMax characters per line exceeded. Received command line was not executed. | Fix the line (often the post processor) or the named setting. |
error:12 | Step rate > 30kHzGrbl '$' setting value cause the step rate to exceed the maximum supported. | Fix the line (often the post processor) or the named setting. |
error:13 | Check DoorSafety door detected as opened and door state initiated. | Fix the line (often the post processor) or the named setting. |
error:14 | Line length exceededBuild info or startup line exceeded EEPROM line length limit. Line not stored. | Fix the line (often the post processor) or the named setting. |
error:15 | Travel exceededJog target exceeds machine travel. Jog command has been ignored. | Fix the line (often the post processor) or the named setting. |
error:16 | Invalid jog commandJog command has no '=' or contains prohibited g-code. | Fix the line (often the post processor) or the named setting. |
error:17 | Setting disabledLaser mode requires PWM output. | Fix the line (often the post processor) or the named setting. |
error:20 | Unsupported commandUnsupported or invalid g-code command found in block. | Fix the line (often the post processor) or the named setting. |
error:21 | Modal group violationMore than one g-code command from same modal group found in block. | Fix the line (often the post processor) or the named setting. |
error:22 | Undefined feed rateFeed rate has not yet been set or is undefined. | Fix the line (often the post processor) or the named setting. |
error:23 | Invalid gcode ID:23G-code command in block requires an integer value. | Fix the line (often the post processor) or the named setting. |
error:24 | Invalid gcode ID:24More than one g-code command that requires axis words found in block. | Fix the line (often the post processor) or the named setting. |
error:25 | Invalid gcode ID:25Repeated g-code word found in block. | Fix the line (often the post processor) or the named setting. |
error:26 | Invalid gcode ID:26No axis words found in block for g-code command or current modal state which requires them. | Fix the line (often the post processor) or the named setting. |
error:27 | Invalid gcode ID:27Line number value is invalid. | Fix the line (often the post processor) or the named setting. |
error:28 | Invalid gcode ID:28G-code command is missing a required value word. | Fix the line (often the post processor) or the named setting. |
error:29 | Invalid gcode ID:29G59.x work coordinate systems are not supported. | Fix the line (often the post processor) or the named setting. |
error:30 | Invalid gcode ID:30G53 only allowed with G0 and G1 motion modes. | Fix the line (often the post processor) or the named setting. |
error:31 | Invalid gcode ID:31Axis words found in block when no command or current modal state uses them. | Fix the line (often the post processor) or the named setting. |
error:32 | Invalid gcode ID:32G2 and G3 arcs require at least one in-plane axis word. | Fix the line (often the post processor) or the named setting. |
error:33 | Invalid gcode ID:33Motion command target is invalid. | Fix the line (often the post processor) or the named setting. |
error:34 | Invalid gcode ID:34Arc radius value is invalid. | Fix the line (often the post processor) or the named setting. |
error:35 | Invalid gcode ID:35G2 and G3 arcs require at least one in-plane offset word. | Fix the line (often the post processor) or the named setting. |
error:36 | Invalid gcode ID:36Unused value words found in block. | Fix the line (often the post processor) or the named setting. |
error:37 | Invalid gcode ID:37G43.1 dynamic tool length offset is not assigned to configured tool length axis. | Fix the line (often the post processor) or the named setting. |
error:38 | Invalid gcode ID:38Tool number greater than max supported value. | Fix the line (often the post processor) or the named setting. |
Source: Grbl v1.1 — tableaux officiels des codes d’alarme et d’erreur (dépôt gnea/grbl) · consulted November 26, 2026
Mach4 — Mach4 (messages) 1
Mach3 and Mach4 have no public numeric code list. Messages show in the message bar and the log (Diagnostic > Logging).
| Code | Meaning | What to check |
|---|---|---|
Soft limits | (avertissement au chargement)On load, Mach4 checks whether the toolpath exceeds soft limits and warns. In motion, the axis slows and stops at the limit (about a ½ in window). | Check the work offset; jog the axis away. |
Source: Newfangled Solutions — Mach4 CNC Controller Operation Manual (section 5.2 Soft Limits) · consulted November 26, 2026
Brands without a verifiable public list
We publish no code we have not read in an official document. For these brands, use the manual shipped with the machine or the builder’s service:
- Trumpf (TruLaser, TruBend) — No official public alarm list found; documentation is customer-only (MyTRUMPF).
- Amada (AMNC, HG, FBDIII) — No official public list found; manuals ship with the machine.
- Mazak (Matrix, Smooth) — No official public list for current controls.
- Torchmate / Avid CNC — No numeric code list published; see the Torchmate and Avid guide and the plasma source in use.
- FANUC — alarmes de la commande (PS, SV, OT…) — In your model’s maintenance manual (e.g. B-64605EN for 0i-F), which FANUC does not publish openly.
Missing or mistranslated code? Send us the manual page.