CoupeFab

Troubleshooting · plasma

Plasma troubleshooting: dross, bevel, top spatter, arc loss

Identify the dross type (low speed, high speed, top spatter), read the cut angle, correct height, speed and current in small steps, and fix arc loss and fast wear — based on Hypertherm’s guides.

Reviewed 3 min read Level : Intermediate DraftWritten by CoupeFab from the official documents cited. Technical review by Michaël Brassard pending.

Most plasma cut defects come from three variables: speed, height (arc voltage) and current — plus consumable condition. Hypertherm says so clearly in its cut-quality guides. This guide follows their logic: identify the symptom, then correct one variable at a time, in small steps.

First: the four basic checks

  1. Correct cut direction (profiles clockwise, holes counter-clockwise with a standard swirl ring) — see Lead-ins and pierce.
  2. Right process for material and thickness: exact chart row, right gases, right consumable part numbers.
  3. Consumables in good shape — see Consumables.
  4. Torch square to the plate, plate flat and well grounded.

Reading dross

TypeWhat it looks likeMain causeFix (Hypertherm)
Low-speed drossThick, bubbly bead under the cut; comes off in big chunks; vertical lag linesSpeed too slow (also: current too high, torch too low)Increase speed in 5 ipm steps; raise height by 1/16 in or 5 V; lower current in 10 A steps
High-speed drossSmall, hard, thin bead, hard to remove; “S” lag linesSpeed too fast (also: current too low, torch too high)Check nozzle wear first; lower speed in 5 ipm steps; lower height; raise current without exceeding 95% of the nozzle rating
Top spatterFine droplets on the top edge, easy to removeWorn nozzle, speed too fast, torch too highCheck the nozzle; reduce speed and height

Between the extremes lies a dross-free window: narrower on stainless and aluminum, wider on mild steel. A little dross in corners is normal, as speed drops through turns.

Reading the cut angle (bevel)

ObservationLikely causeFix
Negative angle (part wider at top)Torch too lowRaise height (or voltage)
Positive angle (part wider at bottom)Torch too highLower height (or voltage)
Bevel on one side onlyTorch not square, or wrong cut directionSquare the torch; reverse direction
Bevel growing during the jobConsumables wearing (voltage rises)Replace; adjust voltage

Hypertherm notes that arc voltage must be readjusted as consumables wear to keep the same height.

Arc loss and interrupted cuts

  • Speed far too fast or slow: the arc goes out (not enough metal to sustain a transferred arc).
  • Ground: loose clamp, rusty plate, slat insulated by slag.
  • Air: pressure drops during the cut, water or oil in the air.
  • THC diving or climbing: lock it in corners and holes, set the speed cutoff.
  • Pierce height or delay wrong — see Lead-ins and pierce.

Fast consumable wear

SymptomFrequent causes
Electrode pits fastWet or oily air, too many starts, arc held off the plate
Nozzle orifice ovalPiercing too low, plate contact (THC), current above rating
Spatter stuck to the shieldPierce height too low, delay too short

Error codes and alarms

Codes taken only from public manuals and official documents, with the source under each table. Exact numbers and meanings can vary with software version and machine builder: when in doubt, your machine’s manual wins.

Hypertherm — Powermax65/85/105 SYNC 33

Format 0-nn-n: the last digit narrows the cause. 1-nn-n, 2-nn-n and 3-nn-n codes are internal faults: service required.

Hypertherm — Powermax65/85/105 SYNC
CodeMeaningWhat to check
0-11-0AlertRemote operating mode not allowed for the cartridge (1 = cut, 2 = expanded metal, 3 = gouge).Check the process variables sent by the CNC.
0-11-1AlertRemote output current not allowed for the cartridge.Check the CNC process variables.
0-11-2AlertRemote gas pressure not allowed.Check the CNC process variables.
0-12-1AlertGas output pressure low.Increase inlet pressure.
0-12-2AlertGas output pressure high.Decrease inlet pressure.
0-12-3AlertGas output pressure unstable.Check regulator, lines and air supply.
0-13-0AlertAC input power unstable (warning).Check the line or generator.
0-14-0AlertCartridge installation problem.Reinstall the cartridge; reduce nearby electrical noise.
0-14-1AlertCartridge not recognized.Clean and inspect the cartridge; set current manually if needed.
0-19-9StopsInput power stopped or power-board hardware protection.Check input power; if repeated, service.
0-20-0AlertGas pressure below the minimum for the process, torch, lead length and cartridge.Increase inlet pressure; check leaks and filters.
0-21-0StopsGas flow lost while cutting (excessive arc-voltage change).Check gas supply and lines.
0-22-0StopsNo gas supply input.Connect and open the gas supply.
0-30-0StopsTorch stuck open (TSO): nozzle and electrode stay touching after the start signal.Power off, replace the cartridge, power on.
0-30-1StopsTorch stuck closed (TSC): nozzle and electrode separate after the start signal.Power off, correct, power on; if persistent, torch damaged.
0-32-0StopsCartridge at end of life.Install a new cartridge.
0-32-1AlertA cartridge that already had 0-32-0 is reinstalled.Install a new cartridge.
0-40-0 / 0-40-1StopsBoost PFC IGBT too cold / too hot (CSA and 105 SYNC CE models).Let it cool with power on (fan) or warm the room; clear the louvres.
0-40-2 / 0-40-3StopsInverter IGBT too cold / too hot.Same steps: cooling, ambient temperature, fan clearance.
0-50-0StopsCartridge off, torch disconnected, or torch lock yellow at restart.Power off, install the cartridge, power on.
0-50-1StopsTorch-lock switch in the yellow (X) position.Set the switch to green (ready).
0-50-2InfoLock switch green but torch not ready to fire.Hand torch: release and press the trigger. Machine: send STOP from the CNC if the code stays.
0-50-3InfoSystem is reading cartridge data.Wait (up to 6 s with electrical noise).
0-51-0StopsStart signal present at power-up (“stuck start”).Release the trigger or remove the CNC signal, then restart.
0-52-0StopsTorch not connected.Plug the torch into FastConnect and restart.
0-60-0StopsAC input phase loss (three-phase models).Check phases and fuses.
0-60-1StopsAC input voltage too low.Check the line.
0-60-2StopsAC input voltage too high.Check the line.
0-61-0StopsAC input unstable: shutdown.Power down and fix the line problem first.
0-98-0AlertInternal communication failure (LCD/control PCB and DSP PCB).Power off 20 s, restart; if persistent, service.
0-98-1AlertRF communication failure between cartridge and torch.Clean and reinstall the cartridge.
0-98-2AlertCommunication failure between torch and power supply.Check the torch connection.
1-nn-n · 2-nn-n · 3-nn-nStopsMajor internal component fault in the power supply.Service by a qualified technician.

Source: Hypertherm — Powermax65/85/105 SYNC Operator Manual (810470, rév. 4.1, juillet 2026) · consulted November 26, 2026

Hypertherm — Powermax65/85/105 (pre-SYNC) 16

Labels from Hypertherm’s machine-side reference guide; detailed solutions are in section 5 of the operator manual.

Hypertherm — Powermax65/85/105 (pre-SYNC)
CodeMeaningWhat to check
0-12Low input gas pressure: warningLow input gas pressure (warning).See section 5 of the operator manual.
0-13AC input unstable: warningAC input unstable (warning).See section 5 of the operator manual.
0-19Power board hardware protectionPower board hardware protection.See section 5 of the operator manual.
0-20Low gas pressureLow gas pressure.See section 5 of the operator manual.
0-21Gas flow lost while cuttingGas flow lost while cutting.See section 5 of the operator manual.
0-22No gas inputNo gas input.See section 5 of the operator manual.
0-30Torch consumables stuckConsumables stuck (torch stuck open or closed).See section 5 of the operator manual.
0-32End of consumable lifeEnd of consumable life.See section 5 of the operator manual.
0-40Over temperaturePower supply temperature out of range.See section 5 of the operator manual.
0-50Retaining cap offRetaining cap off or not fully threaded.See section 5 of the operator manual.
0-51Start/trigger signal on at power upStart/trigger signal on at power-up.See section 5 of the operator manual.
0-52Torch not connectedTorch not connected.See section 5 of the operator manual.
0-60AC input voltage errorAC input voltage error (phase loss, over- or under-voltage).See section 5 of the operator manual.
0-61AC input unstable: shutdownAC input unstable: shutdown.See section 5 of the operator manual.
0-98Internal communication failureInternal communication failure.See section 5 of the operator manual.
0-99System hardware fault – service requiredMajor hardware fault: service required.See section 5 of the operator manual.

Source: Hypertherm — Powermax machine-side reference guide, Powermax65/85/105 · consulted November 26, 2026

Hypertherm — XPR170 / XPR300 / XPR460 (diagnostic codes) 169

Message as shown (in English) on the CNC or XPR web interface. Priorities: Info, Alert, Error, Failure (the arc cannot start). Keep XPR firmware current: some codes come from old firmware.

Hypertherm — XPR170 / XPR300 / XPR460 (diagnostic codes)
CodeMeaningWhat to check
500FailureGCC->Main CAN t/oCAN communication lost between the main board and a module (gas console GCC, torch console TCC, chopper Ch).Follow the manual’s CAN troubleshooting; check cables and termination.
501FailureMix->Main CAN t/oCAN communication lost between the main board and a module (gas console GCC, torch console TCC, chopper Ch).Follow the manual’s CAN troubleshooting; check cables and termination.
503FailureTCC->Main CAN t/oCAN communication lost between the main board and a module (gas console GCC, torch console TCC, chopper Ch).Follow the manual’s CAN troubleshooting; check cables and termination.
504FailureCh1->Main CAN t/oCAN communication lost between the main board and a module (gas console GCC, torch console TCC, chopper Ch).Follow the manual’s CAN troubleshooting; check cables and termination.
505FailureCh2->Main CAN t/oCAN communication lost between the main board and a module (gas console GCC, torch console TCC, chopper Ch).Follow the manual’s CAN troubleshooting; check cables and termination.
507FailureMain no CANCAN communication lost between the main board and a module (gas console GCC, torch console TCC, chopper Ch).Follow the manual’s CAN troubleshooting; check cables and termination.
508ErrorCAN BusyCAN communication lost between the main board and a module (gas console GCC, torch console TCC, chopper Ch).Follow the manual’s CAN troubleshooting; check cables and termination.
510FailureMain->GCC CAN t/oCAN communication lost between the main board and a module (gas console GCC, torch console TCC, chopper Ch).Follow the manual’s CAN troubleshooting; check cables and termination.
511FailureMain->Mix CAN t/oCAN communication lost between the main board and a module (gas console GCC, torch console TCC, chopper Ch).Follow the manual’s CAN troubleshooting; check cables and termination.
513FailureMain->TCC CAN t/oCAN communication lost between the main board and a module (gas console GCC, torch console TCC, chopper Ch).Follow the manual’s CAN troubleshooting; check cables and termination.
514FailureMain->Ch1 CAN t/oCAN communication lost between the main board and a module (gas console GCC, torch console TCC, chopper Ch).Follow the manual’s CAN troubleshooting; check cables and termination.
515FailureMain->Ch2 CAN t/oCAN communication lost between the main board and a module (gas console GCC, torch console TCC, chopper Ch).Follow the manual’s CAN troubleshooting; check cables and termination.
520AlertIgnite t/o (no pilot arc)Ignition: no pilot arc, no arc transfer, or high frequency on too long.Check consumables, pierce height, ground and gas.
521AlertPilot arc t/o (no arc transfer)Ignition: no pilot arc, no arc transfer, or high frequency on too long.Check consumables, pierce height, ground and gas.
522AlertPreflow t/oTimeout during a gas step (preflow, purge).Check pressures and leaks (manual procedure).
523ErrorPreflow purge t/oTimeout during a gas step (preflow, purge).Check pressures and leaks (manual procedure).
524ErrorCutflow purge t/oTimeout during a gas step (preflow, purge).Check pressures and leaks (manual procedure).
525ErrorInert gas purge t/oTimeout during a gas step (preflow, purge).Check pressures and leaks (manual procedure).
530AlertLow psi–Line AGas or water pressure out of range (console inlet or outlet).Set supply pressures per the process; check regulators and lines.
531AlertLow psi–Line BGas or water pressure out of range (console inlet or outlet).Set supply pressures per the process; check regulators and lines.
532AlertLow psi–H2OGas or water pressure out of range (console inlet or outlet).Set supply pressures per the process; check regulators and lines.
533AlertLow psi–F5Gas or water pressure out of range (console inlet or outlet).Set supply pressures per the process; check regulators and lines.
534AlertLow psi–ShieldGas or water pressure out of range (console inlet or outlet).Set supply pressures per the process; check regulators and lines.
540ErrorLow flow 1–CoolantCoolant: flow too low or too high, or level low.Fill the reservoir; check filter, pump and lines.
542FailureLow flow–CoolantCoolant: flow too low or too high, or level low.Fill the reservoir; check filter, pump and lines.
543ErrorHigh flow 1–CoolantCoolant: flow too low or too high, or level low.Fill the reservoir; check filter, pump and lines.
544FailureHigh flow–CoolantCoolant: flow too low or too high, or level low.Fill the reservoir; check filter, pump and lines.
550AlertNo plasma arcIgnition: no pilot arc, no arc transfer, or high frequency on too long.Check consumables, pierce height, ground and gas.
552AlertDC below limit–Ch1Abnormal chopper current (none, too low, too high, present at idle); often worn consumables.Inspect and replace consumables; follow the manual’s chopper-current procedure.
553AlertDC below limit–Ch2Abnormal chopper current (none, too low, too high, present at idle); often worn consumables.Inspect and replace consumables; follow the manual’s chopper-current procedure.
555FailureDC exceeds limit–Ch1Abnormal chopper current (none, too low, too high, present at idle); often worn consumables.Inspect and replace consumables; follow the manual’s chopper-current procedure.
556FailureDC exceeds limit–Ch2Abnormal chopper current (none, too low, too high, present at idle); often worn consumables.Inspect and replace consumables; follow the manual’s chopper-current procedure.
560ErrorOver temp–Ch1Component over-temperature (chopper, inductor, transformer, coolant).Check ventilation, fans, coolant and heat-sink cleanliness.
561ErrorOver temp–Ch2Component over-temperature (chopper, inductor, transformer, coolant).Check ventilation, fans, coolant and heat-sink cleanliness.
570AlertStart on powerupStart signal on at power-up, or removed during a step.Check the CNC start signal.
571AlertStart on wait-startStart signal on at power-up, or removed during a step.Check the CNC start signal.
574InfoStart removed preflowStart signal on at power-up, or removed during a step.Check the CNC start signal.
575InfoStart removed igniteStart signal on at power-up, or removed during a step.Check the CNC start signal.
576InfoStart removed pilotStart signal on at power-up, or removed during a step.Check the CNC start signal.
577InfoStart removed ramp upStart signal on at power-up, or removed during a step.Check the CNC start signal.

See all 169 codes Hypertherm →

Source: Hypertherm — XPR300 Instruction Manual, tableau « Diagnostic codes » (version en ligne) · consulted November 26, 2026

ESAB — Cutmaster 40 and Cutmaster 60i 19

The two models use different codes: check the rating plate.

ESAB — Cutmaster 40 and Cutmaster 60i
CodeMeaningWhat to check
HIOver Temp (Cutmaster 40)Heatsink or transformer over-temperature.Let it cool; respect the duty cycle.
PIPParts In Place (Cutmaster 40)Shield cup removed.Refit and tighten the shield cup.
PICParts In Contact (Cutmaster 40)Tip not touching the electrode at start-up (often tip missing).Install tip and electrode.
SCCTrigger Fault (Cutmaster 40)Trigger pulled at start-up or while a fault clears.Release the trigger.
LoPGas Fault (Cutmaster 40)Consumables do not separate when gas flows (gas not connected or pressure too high).Connect gas; set inlet to 120 psi.
E02Bus Fault (Cutmaster 40)Bus voltage below about 360 V.Authorized service center.
E03Bias Fault (Cutmaster 40)Bias voltage below about 13.5 V.Authorized service center.
E06Low Line Voltage (Cutmaster 40)Input voltage too low.Check input power.
E07High Line Voltage (Cutmaster 40)Input voltage too high.Check input power.
E001Over Temp (Cutmaster 60i)Ambient too hot, duty cycle exceeded, fan or internal fault.Let it cool; check the fan.
E002Input Fault (Cutmaster 60i)Input voltage out of range or low bus; 1/3-phase jumpers J300 set wrong.Check the line and jumpers.
E004PIP Fault (Cutmaster 60i)Shield cup missing or loose.Tighten the cup; otherwise torch and leads.
E005PIC Fault (Cutmaster 60i)Tip, start cartridge or electrode missing or worn; inlet pressure too high.Check consumables and pressure.
E009Fan Fault (Cutmaster 60i)Fan failed or disconnected.Authorized service center.
E010Low Output Current (Cutmaster 60i)Work current below setting (shorted pilot switch or current sensor).Authorized service center.
E012Output Fault (Cutmaster 60i)Tip-to-electrode voltage too low: consumables not separating, stuck cartridge, shorted torch.Power off, bleed pressure, check the start cartridge.
E014Trigger Fault (Cutmaster 60i)Trigger (start signal) active at start-up.Release the trigger or CNC signal.
E016Pressure Fault (Cutmaster 60i)Air pressure too low for the selected settings.Increase supply pressure.
E024 / E031Internal Error (Cutmaster 60i)Internal error (fault lights flashing).Turn off and on; if persistent, service.

Sources: ESAB — CUTMASTER 40 Operating Manual (0-5557); ESAB — CUTMASTER 60i Operating Manual (0-5562, rév. AA, 2019) · consulted November 26, 2026

Lincoln Electric — Tomahawk 1000 (status lights) 6

The Tomahawk 1000 shows no numbers: it reports faults with steady or blinking lights.

Lincoln Electric — Tomahawk 1000 (status lights)
CodeMeaningWhat to check
Vert clignotant · green blinkingInput voltage out of range; restarts by itself when voltage returns.Check input power.
Rouge clignotant · red blinkingInternal auxiliary undervoltage.Turn off then on.
Jaune thermique · yellow thermalOverheated, output disabled (duty cycle exceeded).Leave on to cool.
Jaune pression · yellow gas pressureGas pressure out of range; automatic 10 s purge to adjust.Adjust pressure during the purge.
Jaune PIP · yellow PIPConsumables not installed correctly (shield cup).Hand-tighten the cup, not too hard; restarts after 5 s.
Vert fixe + rouge et jaune clignotants · green on + red and yellow blinkingPilot arc did not transfer within 4 s; stopped to protect the torch.Release the trigger and try again.

Source: Lincoln Electric — Tomahawk 1000 Operator’s Manual (IM10026-A; copie publique) · consulted November 26, 2026

Search a code across all brands →

Troubleshooting procedure

  1. Do the four basic checks.
  2. Identify the dross type or angle on a straight test cut.
  3. Correct the main variable (often speed) in small steps.
  4. If no effect, correct height, then current.
  5. Still no effect: replace electrode and nozzle, check the air.
  6. Save the working combination in the CAM tool library.

FAQ

Why more dross near the end of the sheet?

The plate heats up during the job; Hypertherm notes more dross may form on later cuts. Spread cuts across the sheet (Nesting).

Does the grade matter?

Yes: chemistry, surface condition and flatness change the dross-free window, even at the same thickness.

Sources

Spotted an error or want something added? Tell us →

One guide a week, French-first

New guides, used equipment in Quebec and price moves. No third-party ads.

CASL compliance: the box is not pre-checked. Nothing is sent without this express consent.