Troubleshooting · plasma
Plasma troubleshooting: dross, bevel, top spatter, arc loss
Identify the dross type (low speed, high speed, top spatter), read the cut angle, correct height, speed and current in small steps, and fix arc loss and fast wear — based on Hypertherm’s guides.
Most plasma cut defects come from three variables: speed, height (arc voltage) and current — plus consumable condition. Hypertherm says so clearly in its cut-quality guides. This guide follows their logic: identify the symptom, then correct one variable at a time, in small steps.
First: the four basic checks
- Correct cut direction (profiles clockwise, holes counter-clockwise with a standard swirl ring) — see Lead-ins and pierce.
- Right process for material and thickness: exact chart row, right gases, right consumable part numbers.
- Consumables in good shape — see Consumables.
- Torch square to the plate, plate flat and well grounded.
Reading dross
| Type | What it looks like | Main cause | Fix (Hypertherm) |
|---|---|---|---|
| Low-speed dross | Thick, bubbly bead under the cut; comes off in big chunks; vertical lag lines | Speed too slow (also: current too high, torch too low) | Increase speed in 5 ipm steps; raise height by 1/16 in or 5 V; lower current in 10 A steps |
| High-speed dross | Small, hard, thin bead, hard to remove; “S” lag lines | Speed too fast (also: current too low, torch too high) | Check nozzle wear first; lower speed in 5 ipm steps; lower height; raise current without exceeding 95% of the nozzle rating |
| Top spatter | Fine droplets on the top edge, easy to remove | Worn nozzle, speed too fast, torch too high | Check the nozzle; reduce speed and height |
Between the extremes lies a dross-free window: narrower on stainless and aluminum, wider on mild steel. A little dross in corners is normal, as speed drops through turns.
Reading the cut angle (bevel)
| Observation | Likely cause | Fix |
|---|---|---|
| Negative angle (part wider at top) | Torch too low | Raise height (or voltage) |
| Positive angle (part wider at bottom) | Torch too high | Lower height (or voltage) |
| Bevel on one side only | Torch not square, or wrong cut direction | Square the torch; reverse direction |
| Bevel growing during the job | Consumables wearing (voltage rises) | Replace; adjust voltage |
Hypertherm notes that arc voltage must be readjusted as consumables wear to keep the same height.
Arc loss and interrupted cuts
- Speed far too fast or slow: the arc goes out (not enough metal to sustain a transferred arc).
- Ground: loose clamp, rusty plate, slat insulated by slag.
- Air: pressure drops during the cut, water or oil in the air.
- THC diving or climbing: lock it in corners and holes, set the speed cutoff.
- Pierce height or delay wrong — see Lead-ins and pierce.
Fast consumable wear
| Symptom | Frequent causes |
|---|---|
| Electrode pits fast | Wet or oily air, too many starts, arc held off the plate |
| Nozzle orifice oval | Piercing too low, plate contact (THC), current above rating |
| Spatter stuck to the shield | Pierce height too low, delay too short |
Error codes and alarms
Codes taken only from public manuals and official documents, with the source under each table. Exact numbers and meanings can vary with software version and machine builder: when in doubt, your machine’s manual wins.
Hypertherm — Powermax65/85/105 SYNC 33
Format 0-nn-n: the last digit narrows the cause. 1-nn-n, 2-nn-n and 3-nn-n codes are internal faults: service required.
| Code | Meaning | What to check |
|---|---|---|
0-11-0Alert | Remote operating mode not allowed for the cartridge (1 = cut, 2 = expanded metal, 3 = gouge). | Check the process variables sent by the CNC. |
0-11-1Alert | Remote output current not allowed for the cartridge. | Check the CNC process variables. |
0-11-2Alert | Remote gas pressure not allowed. | Check the CNC process variables. |
0-12-1Alert | Gas output pressure low. | Increase inlet pressure. |
0-12-2Alert | Gas output pressure high. | Decrease inlet pressure. |
0-12-3Alert | Gas output pressure unstable. | Check regulator, lines and air supply. |
0-13-0Alert | AC input power unstable (warning). | Check the line or generator. |
0-14-0Alert | Cartridge installation problem. | Reinstall the cartridge; reduce nearby electrical noise. |
0-14-1Alert | Cartridge not recognized. | Clean and inspect the cartridge; set current manually if needed. |
0-19-9Stops | Input power stopped or power-board hardware protection. | Check input power; if repeated, service. |
0-20-0Alert | Gas pressure below the minimum for the process, torch, lead length and cartridge. | Increase inlet pressure; check leaks and filters. |
0-21-0Stops | Gas flow lost while cutting (excessive arc-voltage change). | Check gas supply and lines. |
0-22-0Stops | No gas supply input. | Connect and open the gas supply. |
0-30-0Stops | Torch stuck open (TSO): nozzle and electrode stay touching after the start signal. | Power off, replace the cartridge, power on. |
0-30-1Stops | Torch stuck closed (TSC): nozzle and electrode separate after the start signal. | Power off, correct, power on; if persistent, torch damaged. |
0-32-0Stops | Cartridge at end of life. | Install a new cartridge. |
0-32-1Alert | A cartridge that already had 0-32-0 is reinstalled. | Install a new cartridge. |
0-40-0 / 0-40-1Stops | Boost PFC IGBT too cold / too hot (CSA and 105 SYNC CE models). | Let it cool with power on (fan) or warm the room; clear the louvres. |
0-40-2 / 0-40-3Stops | Inverter IGBT too cold / too hot. | Same steps: cooling, ambient temperature, fan clearance. |
0-50-0Stops | Cartridge off, torch disconnected, or torch lock yellow at restart. | Power off, install the cartridge, power on. |
0-50-1Stops | Torch-lock switch in the yellow (X) position. | Set the switch to green (ready). |
0-50-2Info | Lock switch green but torch not ready to fire. | Hand torch: release and press the trigger. Machine: send STOP from the CNC if the code stays. |
0-50-3Info | System is reading cartridge data. | Wait (up to 6 s with electrical noise). |
0-51-0Stops | Start signal present at power-up (“stuck start”). | Release the trigger or remove the CNC signal, then restart. |
0-52-0Stops | Torch not connected. | Plug the torch into FastConnect and restart. |
0-60-0Stops | AC input phase loss (three-phase models). | Check phases and fuses. |
0-60-1Stops | AC input voltage too low. | Check the line. |
0-60-2Stops | AC input voltage too high. | Check the line. |
0-61-0Stops | AC input unstable: shutdown. | Power down and fix the line problem first. |
0-98-0Alert | Internal communication failure (LCD/control PCB and DSP PCB). | Power off 20 s, restart; if persistent, service. |
0-98-1Alert | RF communication failure between cartridge and torch. | Clean and reinstall the cartridge. |
0-98-2Alert | Communication failure between torch and power supply. | Check the torch connection. |
1-nn-n · 2-nn-n · 3-nn-nStops | Major internal component fault in the power supply. | Service by a qualified technician. |
Source: Hypertherm — Powermax65/85/105 SYNC Operator Manual (810470, rév. 4.1, juillet 2026) · consulted November 26, 2026
Hypertherm — Powermax65/85/105 (pre-SYNC) 16
Labels from Hypertherm’s machine-side reference guide; detailed solutions are in section 5 of the operator manual.
| Code | Meaning | What to check |
|---|---|---|
0-12 | Low input gas pressure: warningLow input gas pressure (warning). | See section 5 of the operator manual. |
0-13 | AC input unstable: warningAC input unstable (warning). | See section 5 of the operator manual. |
0-19 | Power board hardware protectionPower board hardware protection. | See section 5 of the operator manual. |
0-20 | Low gas pressureLow gas pressure. | See section 5 of the operator manual. |
0-21 | Gas flow lost while cuttingGas flow lost while cutting. | See section 5 of the operator manual. |
0-22 | No gas inputNo gas input. | See section 5 of the operator manual. |
0-30 | Torch consumables stuckConsumables stuck (torch stuck open or closed). | See section 5 of the operator manual. |
0-32 | End of consumable lifeEnd of consumable life. | See section 5 of the operator manual. |
0-40 | Over temperaturePower supply temperature out of range. | See section 5 of the operator manual. |
0-50 | Retaining cap offRetaining cap off or not fully threaded. | See section 5 of the operator manual. |
0-51 | Start/trigger signal on at power upStart/trigger signal on at power-up. | See section 5 of the operator manual. |
0-52 | Torch not connectedTorch not connected. | See section 5 of the operator manual. |
0-60 | AC input voltage errorAC input voltage error (phase loss, over- or under-voltage). | See section 5 of the operator manual. |
0-61 | AC input unstable: shutdownAC input unstable: shutdown. | See section 5 of the operator manual. |
0-98 | Internal communication failureInternal communication failure. | See section 5 of the operator manual. |
0-99 | System hardware fault – service requiredMajor hardware fault: service required. | See section 5 of the operator manual. |
Source: Hypertherm — Powermax machine-side reference guide, Powermax65/85/105 · consulted November 26, 2026
Hypertherm — XPR170 / XPR300 / XPR460 (diagnostic codes) 169
Message as shown (in English) on the CNC or XPR web interface. Priorities: Info, Alert, Error, Failure (the arc cannot start). Keep XPR firmware current: some codes come from old firmware.
| Code | Meaning | What to check |
|---|---|---|
500Failure | GCC->Main CAN t/oCAN communication lost between the main board and a module (gas console GCC, torch console TCC, chopper Ch). | Follow the manual’s CAN troubleshooting; check cables and termination. |
501Failure | Mix->Main CAN t/oCAN communication lost between the main board and a module (gas console GCC, torch console TCC, chopper Ch). | Follow the manual’s CAN troubleshooting; check cables and termination. |
503Failure | TCC->Main CAN t/oCAN communication lost between the main board and a module (gas console GCC, torch console TCC, chopper Ch). | Follow the manual’s CAN troubleshooting; check cables and termination. |
504Failure | Ch1->Main CAN t/oCAN communication lost between the main board and a module (gas console GCC, torch console TCC, chopper Ch). | Follow the manual’s CAN troubleshooting; check cables and termination. |
505Failure | Ch2->Main CAN t/oCAN communication lost between the main board and a module (gas console GCC, torch console TCC, chopper Ch). | Follow the manual’s CAN troubleshooting; check cables and termination. |
507Failure | Main no CANCAN communication lost between the main board and a module (gas console GCC, torch console TCC, chopper Ch). | Follow the manual’s CAN troubleshooting; check cables and termination. |
508Error | CAN BusyCAN communication lost between the main board and a module (gas console GCC, torch console TCC, chopper Ch). | Follow the manual’s CAN troubleshooting; check cables and termination. |
510Failure | Main->GCC CAN t/oCAN communication lost between the main board and a module (gas console GCC, torch console TCC, chopper Ch). | Follow the manual’s CAN troubleshooting; check cables and termination. |
511Failure | Main->Mix CAN t/oCAN communication lost between the main board and a module (gas console GCC, torch console TCC, chopper Ch). | Follow the manual’s CAN troubleshooting; check cables and termination. |
513Failure | Main->TCC CAN t/oCAN communication lost between the main board and a module (gas console GCC, torch console TCC, chopper Ch). | Follow the manual’s CAN troubleshooting; check cables and termination. |
514Failure | Main->Ch1 CAN t/oCAN communication lost between the main board and a module (gas console GCC, torch console TCC, chopper Ch). | Follow the manual’s CAN troubleshooting; check cables and termination. |
515Failure | Main->Ch2 CAN t/oCAN communication lost between the main board and a module (gas console GCC, torch console TCC, chopper Ch). | Follow the manual’s CAN troubleshooting; check cables and termination. |
520Alert | Ignite t/o (no pilot arc)Ignition: no pilot arc, no arc transfer, or high frequency on too long. | Check consumables, pierce height, ground and gas. |
521Alert | Pilot arc t/o (no arc transfer)Ignition: no pilot arc, no arc transfer, or high frequency on too long. | Check consumables, pierce height, ground and gas. |
522Alert | Preflow t/oTimeout during a gas step (preflow, purge). | Check pressures and leaks (manual procedure). |
523Error | Preflow purge t/oTimeout during a gas step (preflow, purge). | Check pressures and leaks (manual procedure). |
524Error | Cutflow purge t/oTimeout during a gas step (preflow, purge). | Check pressures and leaks (manual procedure). |
525Error | Inert gas purge t/oTimeout during a gas step (preflow, purge). | Check pressures and leaks (manual procedure). |
530Alert | Low psi–Line AGas or water pressure out of range (console inlet or outlet). | Set supply pressures per the process; check regulators and lines. |
531Alert | Low psi–Line BGas or water pressure out of range (console inlet or outlet). | Set supply pressures per the process; check regulators and lines. |
532Alert | Low psi–H2OGas or water pressure out of range (console inlet or outlet). | Set supply pressures per the process; check regulators and lines. |
533Alert | Low psi–F5Gas or water pressure out of range (console inlet or outlet). | Set supply pressures per the process; check regulators and lines. |
534Alert | Low psi–ShieldGas or water pressure out of range (console inlet or outlet). | Set supply pressures per the process; check regulators and lines. |
540Error | Low flow 1–CoolantCoolant: flow too low or too high, or level low. | Fill the reservoir; check filter, pump and lines. |
542Failure | Low flow–CoolantCoolant: flow too low or too high, or level low. | Fill the reservoir; check filter, pump and lines. |
543Error | High flow 1–CoolantCoolant: flow too low or too high, or level low. | Fill the reservoir; check filter, pump and lines. |
544Failure | High flow–CoolantCoolant: flow too low or too high, or level low. | Fill the reservoir; check filter, pump and lines. |
550Alert | No plasma arcIgnition: no pilot arc, no arc transfer, or high frequency on too long. | Check consumables, pierce height, ground and gas. |
552Alert | DC below limit–Ch1Abnormal chopper current (none, too low, too high, present at idle); often worn consumables. | Inspect and replace consumables; follow the manual’s chopper-current procedure. |
553Alert | DC below limit–Ch2Abnormal chopper current (none, too low, too high, present at idle); often worn consumables. | Inspect and replace consumables; follow the manual’s chopper-current procedure. |
555Failure | DC exceeds limit–Ch1Abnormal chopper current (none, too low, too high, present at idle); often worn consumables. | Inspect and replace consumables; follow the manual’s chopper-current procedure. |
556Failure | DC exceeds limit–Ch2Abnormal chopper current (none, too low, too high, present at idle); often worn consumables. | Inspect and replace consumables; follow the manual’s chopper-current procedure. |
560Error | Over temp–Ch1Component over-temperature (chopper, inductor, transformer, coolant). | Check ventilation, fans, coolant and heat-sink cleanliness. |
561Error | Over temp–Ch2Component over-temperature (chopper, inductor, transformer, coolant). | Check ventilation, fans, coolant and heat-sink cleanliness. |
570Alert | Start on powerupStart signal on at power-up, or removed during a step. | Check the CNC start signal. |
571Alert | Start on wait-startStart signal on at power-up, or removed during a step. | Check the CNC start signal. |
574Info | Start removed preflowStart signal on at power-up, or removed during a step. | Check the CNC start signal. |
575Info | Start removed igniteStart signal on at power-up, or removed during a step. | Check the CNC start signal. |
576Info | Start removed pilotStart signal on at power-up, or removed during a step. | Check the CNC start signal. |
577Info | Start removed ramp upStart signal on at power-up, or removed during a step. | Check the CNC start signal. |
See all 169 codes Hypertherm →
Source: Hypertherm — XPR300 Instruction Manual, tableau « Diagnostic codes » (version en ligne) · consulted November 26, 2026
ESAB — Cutmaster 40 and Cutmaster 60i 19
The two models use different codes: check the rating plate.
| Code | Meaning | What to check |
|---|---|---|
HI | Over Temp (Cutmaster 40)Heatsink or transformer over-temperature. | Let it cool; respect the duty cycle. |
PIP | Parts In Place (Cutmaster 40)Shield cup removed. | Refit and tighten the shield cup. |
PIC | Parts In Contact (Cutmaster 40)Tip not touching the electrode at start-up (often tip missing). | Install tip and electrode. |
SCC | Trigger Fault (Cutmaster 40)Trigger pulled at start-up or while a fault clears. | Release the trigger. |
LoP | Gas Fault (Cutmaster 40)Consumables do not separate when gas flows (gas not connected or pressure too high). | Connect gas; set inlet to 120 psi. |
E02 | Bus Fault (Cutmaster 40)Bus voltage below about 360 V. | Authorized service center. |
E03 | Bias Fault (Cutmaster 40)Bias voltage below about 13.5 V. | Authorized service center. |
E06 | Low Line Voltage (Cutmaster 40)Input voltage too low. | Check input power. |
E07 | High Line Voltage (Cutmaster 40)Input voltage too high. | Check input power. |
E001 | Over Temp (Cutmaster 60i)Ambient too hot, duty cycle exceeded, fan or internal fault. | Let it cool; check the fan. |
E002 | Input Fault (Cutmaster 60i)Input voltage out of range or low bus; 1/3-phase jumpers J300 set wrong. | Check the line and jumpers. |
E004 | PIP Fault (Cutmaster 60i)Shield cup missing or loose. | Tighten the cup; otherwise torch and leads. |
E005 | PIC Fault (Cutmaster 60i)Tip, start cartridge or electrode missing or worn; inlet pressure too high. | Check consumables and pressure. |
E009 | Fan Fault (Cutmaster 60i)Fan failed or disconnected. | Authorized service center. |
E010 | Low Output Current (Cutmaster 60i)Work current below setting (shorted pilot switch or current sensor). | Authorized service center. |
E012 | Output Fault (Cutmaster 60i)Tip-to-electrode voltage too low: consumables not separating, stuck cartridge, shorted torch. | Power off, bleed pressure, check the start cartridge. |
E014 | Trigger Fault (Cutmaster 60i)Trigger (start signal) active at start-up. | Release the trigger or CNC signal. |
E016 | Pressure Fault (Cutmaster 60i)Air pressure too low for the selected settings. | Increase supply pressure. |
E024 / E031 | Internal Error (Cutmaster 60i)Internal error (fault lights flashing). | Turn off and on; if persistent, service. |
Sources: ESAB — CUTMASTER 40 Operating Manual (0-5557); ESAB — CUTMASTER 60i Operating Manual (0-5562, rév. AA, 2019) · consulted November 26, 2026
Lincoln Electric — Tomahawk 1000 (status lights) 6
The Tomahawk 1000 shows no numbers: it reports faults with steady or blinking lights.
| Code | Meaning | What to check |
|---|---|---|
Vert clignotant · green blinking | Input voltage out of range; restarts by itself when voltage returns. | Check input power. |
Rouge clignotant · red blinking | Internal auxiliary undervoltage. | Turn off then on. |
Jaune thermique · yellow thermal | Overheated, output disabled (duty cycle exceeded). | Leave on to cool. |
Jaune pression · yellow gas pressure | Gas pressure out of range; automatic 10 s purge to adjust. | Adjust pressure during the purge. |
Jaune PIP · yellow PIP | Consumables not installed correctly (shield cup). | Hand-tighten the cup, not too hard; restarts after 5 s. |
Vert fixe + rouge et jaune clignotants · green on + red and yellow blinking | Pilot arc did not transfer within 4 s; stopped to protect the torch. | Release the trigger and try again. |
Source: Lincoln Electric — Tomahawk 1000 Operator’s Manual (IM10026-A; copie publique) · consulted November 26, 2026
Troubleshooting procedure
- Do the four basic checks.
- Identify the dross type or angle on a straight test cut.
- Correct the main variable (often speed) in small steps.
- If no effect, correct height, then current.
- Still no effect: replace electrode and nozzle, check the air.
- Save the working combination in the CAM tool library.
FAQ
Why more dross near the end of the sheet?
The plate heats up during the job; Hypertherm notes more dross may form on later cuts. Spread cuts across the sheet (Nesting).
Does the grade matter?
Yes: chemistry, surface condition and flatness change the dross-free window, even at the same thickness.
Sources
One guide a week, French-first
New guides, used equipment in Quebec and price moves. No third-party ads.