CoupeFab

Troubleshooting · on the floor

Alarm or crash on a CNC machine: the first steps, in order

What to do when an alarm appears or a tool hits: make safe, write down the exact code, read the history, find the cause before RESET, check the machine before restarting. With Haas and Siemens public guidance.

Reviewed 5 min read Level : Beginner DraftWritten by CoupeFab from the official documents cited. Technical review by Michaël Brassard pending.

An alarm is not a button to make go away: it is the control telling you what it saw. The “RESET and restart” reflex wipes out the most useful clue and, after a crash, may restart a misaligned machine. This guide gives a simple order to follow, whether the alarm is a plain message or a tool just hit the part.

The first 5 minutes

  1. Make it safe. If anything is still moving or could move, hit emergency stop. Nobody puts hands in the work area until the machine is stopped and, for any work in the danger zone, locked out (see Lockout (CNESST)).
  2. Don’t press RESET yet. Take a photo of the screen: alarm number and text, program line, axis positions, active tool.
  3. Write down the context: program, tool number, work offset (G54…), what was just changed (tool, offset, program, material).
  4. Read the history. On Haas, the [ALARMS] key opens the Active Alarm, Alarm History (searchable) and Alarm Viewer tabs; the Key History tab shows the last 2000 keystrokes, very handy to see “what we did just before”.
  5. Look up the code in the control manual or the code lookup, then fix the cause. Only then: clear it.

Reading the alarm: what it needs to clear

Controls group alarms by how they clear. Siemens documents this clearly in its SINUMERIK alarm manual (cancel criteria):

Cancel criterion (Siemens)What it means on the floor
Self-clearingThe alarm goes away once the cause is gone (door closed, pressure back).
Clear key or cycle startMessage or warning: read it, fix it, clear it.
RESET then restart the programThe program was interrupted: restart from the right place, not mid-move.
Switch the control off and onDeeper fault (configuration, drive): write the code down before powering off.

On Siemens drives (SINAMICS), the manual separates a fault (drive response, logged in the fault buffer, acknowledged after the fix) from an alarm (a warning that clears itself when the cause disappears). Haas, for its part, often prefixes the axis number on NGC alarms (e.g. 1.108 = alarm 108 on X).

After a crash

A crash, even a slow one, can shift a jaw, bend a tool holder, mark the spindle or move a work offset. Before going back into production:

  1. Back out gently. For a tool stuck in material, Haas says: doors closed, [RESET] to clear alarms, then handle-jog the axis to free tool and part. For the tool changer: [RECOVER] and follow the screen.
  2. Inspect tool and holder: cutting edge, runout on the holder with an indicator, clean taper.
  3. Check the setup: did the vise or fixture move? Re-probe or re-measure the offset (see Work offsets (G54) and On-machine probing).
  4. Check the machine: unusual spindle noise, play, servo alarm coming back. If the spindle or an axis took a hard hit, have it checked before holding tight tolerances again.
  5. Find the cause: Haas lists common crash causes as a wrong tool offset, a wrong work offset and the wrong tool in the spindle.
  6. Restart carefully: reduced feed and rapid, single block through the problem area.

Common mistakes

MistakeConsequence
RESET before writing the code downBlind diagnosis, longer service call
Restarting mid-program without checking positionA second crash
Changing an offset “to see”The real cause (wrong tool, wrong offset) remains
Ignoring an alarm that keeps coming backA small cause turns into a breakdown (lube, filter, air)
Reaching into the zone without lockoutSerious hazard; a legal requirement in Quebec (RSST)

Checklist

  • Machine stopped, area safe (lockout for any work in the danger zone)
  • Photo of the screen: number, text, line, tool, offset
  • Alarm history checked
  • Meaning found in the manual or the code lookup
  • Cause fixed before clearing
  • After a crash: tool, holder, setup and offset checked
  • Restart at reduced feed, single block through the problem area
  • Event logged in the machine logbook

FAQ

Is it bad to power-cycle the control to clear an alarm?

Sometimes that is the intended criterion (Siemens: “POWER ON”). But always write the code down first: some information is lost and service will ask for the exact number.

The alarm keeps coming back. What now?

It is a signal, not a whim: the cause is not fixed. Note when it returns (at start-up, in heavy cuts, at tool change); that context guides the technician.

Where is the full alarm list for my machine?

In the control’s operator or diagnostics manual, and on the control itself (Haas: Alarm Viewer tab). The CoupeFab code lookup gathers publicly published codes.

Sources

Spotted an error or want something added? Tell us →

One guide a week, French-first

New guides, used equipment in Quebec and price moves. No third-party ads.

CASL compliance: the box is not pre-checked. Nothing is sent without this express consent.